Turntable control SmartTurn
Installation and commissioning
Dok-ID:EXPERT-0003-EN-2011
39
A6 – system faults
(pin 11)
Output A6 is switched on if faults are detected that compromise
safe operation of the turntable. System faults can only be
acknowledged on the turntable controller via the reset button.
NOTE!
When the fault occurs the instructions in section ->
Monitor system
must be complied with.
A7 – end lock angle
(pin 13)
The A7 output is switched on if the switch-off angle has reached
the end of the drive roller lock movement.
NOTE!
When the fault occurs the instructions in section ->
Monitoring brake wear
must be complied with.
A8 – position forward
(pin 14)
Output A8 is switched on if the turntable is in the 0 position after
one revolution forward.
A9 – position back
(pin 15)
Output A9 is switched on if the turntable is in the 0-position after
one revolution backward.
The output is not activated in continuous mode.
A10 – sensor in the set lock angle
(pin 17)
The output is set when the sensor is in the lock angle that is set on
switch S1. The signal can be used for a pre-enable. However the
signal does not mean that the turntable is in the defined 0 position.