Parameter Setting Page Field Description
o
IP Address
IP address of the converter, 4 numbers (1-255) separated by '.'. Don’t let it conflict with other devices in the
network.
If DHCP client mode is enabled and a DHCP server is present in the network, this field will be assigned by
DHCP server automatically.
o
Subnet mask
Subnet mask of the converter. “255.255.255.0” is used by default. For small networks “255.255.0.0” for
larger network, 4 numbers (1-255) separated by '.'.
If your IP address is provided by an ISP or the internal network administrator, please check if the
information and type it correct.
If DHCP client mode is enabled and a DHCP server is present in the network, this field will be assigned by
DHCP server automatically.
o
Gateway address
Gateway or Router IP address. 'Gateway' is a device which connects local network to external network. If
you need to communicate with other networks or your device owns a real IP address on the internet, please
check if this information and type it correct. If there's no gateway on the network, leave empty or set to
“0.0.0.0”.
If DHCP client mode is enabled and a DHCP server is present in the network, this field will be assigned by
DHCP server automatically.
o
DHCP client
DHCP client mode can be enabled/disabled. If DHCP is enabled, there has to be a DHCP server in the
network. If DHCP is disabled IP address, Subnet mask, and Gateway address have to be assigned manually.
o
Auto Reset
Auto Reset will reboot the device if it has been disconnected or no data is transmitting for a certain time (1 -
255 minute).
o
Device Name
Device name can be a string of up to 15 characters.
o
Login Password
For security and management issues, you may set the “Login Password”. This administration password is
used to log into the converter. It may be empty or a string of up to 15 characters.
o
Serial I∕O Port 1 (RS422/RS485)
This converter provides one RS422/RS485 port for connecting the serial devices.
Local Port ∕ Socket Mode ∕ Remote IP & Port
This converter provides 1 socket port for the serial connection.
Port number
Socket port assigned for the serial port. It’s a 16-bit number in the ranging from 1 to 65535. The
numbers below 1000 are reserved for special protocols (e.g. 80 is for HTTP protocol), we suggest to use
a number larger than 1000. By default 4660 is used for the serial communication. However it is possible
to use any other number for each serial port.