11
Manuel d’utilisation
PAR COB 630
The light is available to receive the DMX512 signal, connect the DMX connector to the panel which
marked with “DMX IN”, and connect it to the next light, then, connect to the “DMX IN” of next light from
the “DMX OUT”, The DMX signal terminator is recommended when the lighting signal is connecting. It
will avoid to interfere the signal which caused by the electrical noise. DMX terminator is a XLR connector,
connect with a 120∩ resistor between the pin 2 and pin 3 of the XLR connector, and connect it to the
OUTPUT socket of the final light
See picture:
4.
DMX CHANNELS
Channel
Channel address
Function
CH 1
0-255
Dimmer
CH 2
1-255
Strobe
CH 3
1-255
Macro function
CH 4
0-255
Macro function speed
adjust
CH 5
0-255
Red dimming
CH 6
0-255
Green dimming
CH 7
0-255
Blue dimming