background image

to the connected device. 

C. 

To turn off the device, simply unplug it from the power 
port. 
 

9. Pass-Through Technology 

The EXP48PRO and EXP96PRO are equipped with 

“P

ass Through

 

technology. This allows you to charge devices connected to the 
battery while the battery is being charged. The battery will 
automatically detect a power outage and switch to battery power. 
Please note that to get the most life out of your EXP PRO battery, 
we suggest only using this option if there is a concern about a 
power outage. 
 

10. Parallel Connecting Batteries 

(

Daisy 

Chaining

)

 

  

You can parallel connect no more than two batteries by plugging in 
the provided DC charge cord to the charge port on one battery and 
the main power port marked 12V/15A on the other battery in order 
to double the available capacity. 
 

11. Operating the White Light/Emergency Amber 
Flashing Light 

White Light:

 

Press and hold the power button to turn on. Press 

and hold the power button, again, to turn off.  

Emergency Amber Flashing: 

Quickly press the power button 

twice to turn on.  Quickly press the power button twice, again, to 
turn off.  

 

12. Battery Management System (BMS) 

Содержание EXP48PRO

Страница 1: ...EXP PRO Batteries Hand held Power EXP48PRO EXP96PRO User Manual Power to Explore...

Страница 2: ...9 Pass Through Technology 10 Parallel Connecting Batteries Daisy Chaining 11 Operating the White Light Emergency Amber Flashing Light 12 Battery Management System BMS 13 Airline Travel 14 Battery Stor...

Страница 3: ...t information about usage and safety Use the product as described and keep this manual for future reference Before reading through the manual you can begin to charge up your EXP PRO Battery by connect...

Страница 4: ...battery and the other end into the appropriate power source C Charging will begin automatically D Battery is fully charged when all power indicator lights have been solidly lit for at least 30 minute...

Страница 5: ...wing it to easily fit in most backpacks to take with you on your outdoor adventures The panel will provide up to 18V 1 5A It is ideally suited for outdoor life and the unexpected power outage A Open t...

Страница 6: ...on can also be found on the back of each battery DC Output Port DC12V 10A Continuous 15A Peak 5Min Type C Input DC5V 3A 9V 3A 15V 3A 20V 2 25A Type C Output DC5V 3A 9V 3A 12V 3A 15V 3A 20 3V 3A USB Ou...

Страница 7: ...att Hours Wh 25 6 Amp Hours Ah 12V 96 000 Milli Amp Hours mAh 3 2V 8 Powering From the DC Output Port A Plug your device into the main round power port ensuring a secure fit using a 12V cigarette styl...

Страница 8: ...ion if there is a concern about a power outage 10 Parallel Connecting Batteries Daisy Chaining You can parallel connect no more than two batteries by plugging in the provided DC charge cord to the cha...

Страница 9: ...itself and resume normal operation 13 Airline Travel EXP48PRO Up to two of the EXP48PRO batteries can be brought with you in your carry on luggage While the FAA regulations state the limit is 160 wat...

Страница 10: ...apacity We have provided a Notes section for you to keep track of your battery maintenance 15 Safe Use of Lithium Batteries Never expose the battery to liquids especially saltwater This can cause inte...

Страница 11: ...can charge with my EXP PRO battery Cell Phones Go Pros Laptops Tablets Bluetooth Speakers Drones LED Lights CPAP machines BiPAP machines Cameras Air Pods and more Can I use a different charge cord ot...

Страница 12: ...ry B Using the DC power cord specific to the individual PAP machine being powered plug your device into the DC Output Port on the battery ensuring a secure fit C The port s will automatically turn on...

Страница 13: ...0 CPAP Airstart 10 Auto CPAP Aircurve 10 S Bilevel Aircurve 10 Vauto Bilevel RM 9 Fits Models Resmed S9 Escape CPAP with ERP S9 Elite CPAP with ERP S9 Autoset CPAP S9 VPAP S Bilevel DS 12V Fits Models...

Страница 14: ...nverter B Plug the pure sine inverter into the DC output port found on the battery The inverter will convert DC power from the battery to AC power required for the factory AC power cord C Please note...

Страница 15: ...PRO are figured using the average night sleep in the US of 7 hours and with auxiliary features turned off Power requirements will vary greatly from one PAP machine to the next and with different presc...

Страница 16: ...under normal consumer use during the applicable warranty period identified in the Warranty Period section below subject to the exclusions set forth below This warranty statement sets forth EXP PRO s t...

Страница 17: ...to operate during the applicable warranty period due to defect in workmanship or material If a valid claim is made during the applicable period EXP PRO at its options will either 1 repair the product...

Страница 18: ...nless the battery cell is stored at the proper charge level as discusses in section 14 How to Receive Service To obtain warranty service contact our customer service team at orders EXPPROPOWER com The...

Отзывы: