UK |
17
3112008_RHGC_UK
Startup and configuration
System testing
Before any adjustments are made to the system, please follow these procedures:
Turn the chimney fan ON and make sure that it is turning. Increase and decrease the speed of the fan by
adjusting the speed control to make sure the fan is operating properly.
After system testing, Exodraft recommends igniting your fireplace or stove. Follow the guide below for
correct lighting and use of the chimney fan.
Operating the fireplace using the EFC21 controller
B
A
Press the ON/OFF button
•
The operating LED
(B)
will flash GREEN until the correct chimney draught is confirmed.
If it flashes YELLOW, then the Air inlet must be opened.
The operating LED will then become GREEN and the fireplace can be lit.
•
To stop the fan press the ON/OFF
(A)
button.
External ON/OFF switch
•
The ON/OFF
(A)
switch can be used to start, stop and reset the controller.
•
If the external ON/OFF
(A)
switch is used, it has priority over the control panel and the remote control
Note!
The switch must be in the OFF position before the controller can be re-started.
DANGER! Check that the heating appliance (water heater, furnace, etc.) is
working properly after the chimney fan has been switched on. Make sure that
no flue gases are spilling out as this can lead to carbon monoxide poisoning!