4 .6
Electrical wiring
RBV1 must be wired according to existing national requirements .
N
M
L
3 x 1,0
PE
DANGER
If the need arises to replace the original RBV1 cord, use a cord of the same type . Otherwise, the insulation
can melt or erode, exposing the cord itself .
4 .7
Start-up
DANGER
Check the oven to make sure it is working properly, while the RBV1 is running . Make sure that no fumes are
escaping into the room as this can lead to carbon monoxide poisoning .
If the combustion air is drawn from the room, where the appliance is placed, it is essential that the fresh air
intake is guaranteed .
Applicable for stoves or inserts:
1 . Before lighting the fire, turn on the RBV1 (open the air intake completely on the stove)
2 . Place the wood in the stove
3 . Make sure that the RBV1 is turned on, before you attempt lighting the fire . Strike a match inside the stove
and keep it there, noting if the smoke from the match is being drawn towards the top of the stove and out
of the chimney*
4 . Listen carefully as well . You should be able to hear the blade of the RBV1 revolving**
5 . Light the fire and make sure that no smoke is escaping from the stove
6 . Close the doors .
-Is smoke escaping from the closed stove?
- Close the air-intake of the stove
- Open the windows in the room where the oven is located to ventilate the room thoroughly
- If necessary, call for qualified assistance in order to remedy the problem
- If defects are detected, these must be repaired before using the RBV1 and the stove again .
*/** NOTE: If the RBV1 does not draw the smoke from the match towards the top of the stove, or if you cannot hear the
RBV1 running, do not light the fire . Consult the section troubleshooting (section 4 .8 .2 page 38) . If this does not rectify
the problem, call for qualified assistance .
CAUTION
Do not over-heat the stove . Small deposits of soot can kindle and start a chimney fire, which may cause
dangerously high temperatures in the chimney .
If you have experienced a chimney fire, you must ensure that the mechanical and electrical functioning of
the RBV1 is checked . If defects are found, these must be repaired before further use of the RBV1 and the
stove .
3200998-RBV1-DK-SE-NO-UK-DE-20180813
UK •
37
Содержание RBV1
Страница 7: ...1 5 4 Montering af bundflange og wire p RBV1 3 4 x 9 6 3200998 RBV1 DK SE NO UK DE 20180813 DK 7...
Страница 16: ...2 5 4 Montering av motfl ns och vajer p RBV1 3 4 x 9 6 3200998 RBV1 DK SE NO UK DE 20180813 16 SE...
Страница 25: ...3 5 4 Montering av bunnflensen og vaier p r yksugeren 3 4 x 9 6 3200998 RBV1 DK SE NO UK DE 20180813 NO 25...
Страница 34: ...4 5 4 Installing the bottom flange and wire on the RBV1 3 4 x 9 6 3200998 RBV1 DK SE NO UK DE 20180813 34 UK...
Страница 43: ...3200998 RBV1 DK SE NO UK DE 20180813 DE 43 5 5 4 Montage vom Bodenflansch und Drahtseil am RBV1 3 4 x 9 6...
Страница 48: ...3200998 RBV1 DK SE NO UK DE 20180813 48...
Страница 50: ...3200998 RBV1 DK SE NO UK DE 20180813 50...
Страница 51: ...3200998 RBV1 DK SE NO UK DE 20180813 51...