Distributor in USA & Canada
ENERVEX Inc.
1685 Bluegrass Lake Parkway
Alpharetta
GA 30004
P: 770.587.3238
F: 770.587.4731
T: 800.255.2923
[email protected]
www.enervex.com
www.exodraft.com
5. Startup and Configuration
5.1 Pre-operation inspection
After mounting and wiring has been completed, check the control for the following items before applying
power:
• Check for wiring errors.
• Verify that there are no wiring chips, screws, etc. remaining inside the junction boxes.
• Check that all screws and terminal connections are tight.
• Verify that no exposed wire ends are touching other terminals.
Apply power to the control. Let the control be turned on for 12 hours to allow the battery to be charged.
Warning: Make sure the battery is fully charged before using the solid-fuel appliance. Failure to
charge the battery will prevent the control from provide safe operation.
5.2 Setting the Control
Turn the control on by turning the knob clockwise. A “click” is heard when know is turned which indicates the
control is turned on. Adjust the knob to the desired speed. The speed must be set so no smoke escapes the
solid fuel heating appliances (fireplace, stove, wood-fired oven etc.) through the opening into a room. The
smoke should safely be exhausted through the chimney.
The chimney fan will start with a 15 seconds boost to assure proper fan operation. The green LED on the
speed control unit cover will flash
After the 15 seconds the chimney fan will continue to operate at the desired speed.
During appliance operation the speed setting can be adjusted.
5.3
Surveillance
The control constantly monitors the chimney fan operation. It automatically measures the fan speed every
minute and if necessary, it will increase the speed which can be heard as quiet “hick-up” from the fan.
If necessary, the control will increase the speed to full speed for 15 seconds (green LED flashes), after
which, if possible, it will slow the fan speed down to the desired speed.
5.4 alarm Functions
If the green LED flashes during operation (after the 15 seconds initiation) the fan speed is set too low or the
fan wheel is somehow obstructed.
If the red LED flashes and the buzzer sounds, it can be caused by:
• Defective chimney fan
• Disconnected power supply
The control can be reset, and the alarm turned off, by pressing the RESET button for 1-2 seconds.