Warning

To minimise the risk of fire, electric shock, personal injury 

and/or damage to the product please observe the following:

•   Please always read the manual and only use the product in accordance with the 

manufacturer’s instructions. If in doubt, contact one of the Exodraft specialized dealers.

• 

 All installations must be carried out by properly qualifi ed personnel in accordance with 

national legislation and regulations.

• 

This product must be earthed. Get assistance from an qualifi ed electrician when in doubt. 

• 

The chimney fan must always remain switched on when the fireplace is in use.

• 

Ensure that the chimney has been swept before mounting the fan to avoid chimney fires.

•   Prior to servicing the product, disconnect the power and ensure that it cannot accidentally 

be reconnected.

• 

 Exodraft always recommends the use of a smoke alarm when a solid fuel fireplace is 

installed.

•   If the Exodraft fan system has been designed for solid fuel/multi fuel installations, please 

ensure that the design meets the requirements of BS EN15287-1. If this cannot be achie-

ved, a smoke alarm must be installed in the same room as the heat appliance.

•   Note! Fans serving biomass boilers must be cleaned more often due to extensive residue/

soot building. It is essential that a regular inspection and cleaning schedule is implemen-

ted, especially in the early days of usage, to experience how often regular inspections and 

cleaning should be carried out.

UK

Your energy. 

Optimized.

Product information

An Exodraft CFIR Inline fan is intended for use as a true in-line draft inducer. It can be installed in-line in the 

vertical or horizontal section of the fluepipe.
It is specifically designed for applications where reliable and efficient operation, low noise level, low energy 

consumption, variable speed and compact design are critical.

The CFIR is for use with condensing and non-condensing appliances operating at a maximum flue gas

 

temperatures of 600 °C.
Typical uses are mechanical venting of gas-fired or oil-fired boilers and water heaters. The CFIR is for 

indoor or outdoor installation where ambient temperatures are in the range of -40 °C to 50 °C.

The CFIR Inline fan should only be used with appliances operating on Natural Gas, LP-Gas/Butane or fuel 

oil. It should never be used with incinerators or solid-fuel burning equipment. The temperature of the flue 

gases going through the Inline fan should not exceed 600 °C.
The CFIR is not suitable for pulsating boilers.

ATTENTION! It is always recommended to install a CO alarm in the boiler room.

Incorrect firing may result in problems with soot, chimney fires, etc. which might damage the product. 

Please check out this site for advice about lighting and maintaining a fire:

www.exodraft.com

 

Scope of supply

•  Exodraft CFIR Inline fan
•  Installation manual and user instructions

Accessories and spare parts

The table below shows the accessories and spare parts available for the CFIR-models.

Accessories*

Spare parts

Frequency inverter

Inlet cone

Outlet cone

Motor

Impeller

Gasket

U-band

*This manual does not describe the specific use of accessories. We refer to the separate manuals for such components. 

 

For more details contact your Exodraft dealer.

Содержание CFIR

Страница 1: ...Your energy Optimized Chimney Fan Inline fan CFIR UK Read and save these instructions...

Страница 2: ......

Страница 3: ...5 Mounting the inline fan 16 Location connections 16 Vertical installation 17 Horizontal installation 17 Electrical installation 18 Wiring diagram 18 Isolation switch 19 Checking and changing rotation...

Страница 4: ...waste and disposed of according to national legislation to protect the environment and personnel that may come into contact with waste How to use this manual This manual has been prepared based on th...

Страница 5: ...ks a dangerous situation that in the worst case scenario can cause serious personal injury or signi cant damage to the product Electricity hazard High Voltage Marks a situation in which caution is adv...

Страница 6: ...efore mounting the fan to avoid chimney res Prior to servicing the product disconnect the power and ensure that it cannot accidentally be reconnected Exodraft always recommends the use of a smoke alar...

Страница 7: ...ral Gas LP Gas Butane or fuel oil It should never be used with incinerators or solid fuel burning equipment The temperature of the flue gases going through the Inline fan should not exceed 600 C The C...

Страница 8: ...onnel Exodraft reserves the right to change these guidelines without prior notice The warranty and liability does not cover instances regarding personal injury or damage to property or the product tha...

Страница 9: ...ter required Nominal chimney connection w H A B E C D Fig side 5 Technical data A Inlet B Outlet C Motor E Impeller INNER DIAMETER OUTLET AIR FLOW DIRECTION INNER DIAMETER INLET Technical specificatio...

Страница 10: ...00 IP66 Yes CFIR400 7500086 FRK 034 2 20 3 x 400 IP20 No 7500087 FRK 035 2 20 3 x 400 IP66 Yes CFIR500 7500088 FRK 036 4 00 3 x 400 IP20 No 7500089 FRK 037 4 00 3 x 400 IP66 Yes 0 100 200 300 400 500...

Страница 11: ...pacer 3 Motor head shield 4 Motor plate domel 5 Motor mounting plate 6 Insulation 7 Insulation cover 8 Impeller 9 Gasket 10 Inlet cone for impeller 11 CFIR Inline fan 12 U band x2 13 Flange gasket x2...

Страница 12: ...provisions in force in the country where the product is installed must be observed ATTENTION It is always recommended to install a CO alarm in the boiler room Fig nederst side 6 INLET Fan model Cone i...

Страница 13: ...26 662 1557 599 300 CFIR300 STUDS350 CFIR300 MUFFE350 350 5 351 3 343 339 1382 CFIR300 STUDS400 CFIR300 MUFFE400 400 5 401 3 257 251 1208 CFIR400 CFIR400 STUDS400 CFIR400 MUFFE400 CFIR400 UBAND CFIR40...

Страница 14: ...d with the CFIR to be installed by the user The CFIR is for indoor and outdoor installation Unless installed in close proximity to the wall it is discharging through the chimney material used on the d...

Страница 15: ...the 8 x 5 holes are drilled make sure that the curved drainplate follows the shape of the outside of the housing Place the gasket between the drain and the fan housing Use the 8 provided rivets to fa...

Страница 16: ...ceiling or other support To prevent accidental contact with the hot surfaces the supplied warning signs for Hot surface should be placed on the cabinet Follow supplied instruction with the warning sig...

Страница 17: ...the power venter unit Illustration of the CFIR mounted vertically by using threaded M10 rods lock washers and locking hex nuts A tag weld may be placed on the hex nuts for permanent fixation Horizonta...

Страница 18: ...to install a motor over current protection device The CFIR200 CFIR300 CFIR400 and CFIR500 is designed to be regulated through an exodraft frequency inverter and can not be connected directly to mains...

Страница 19: ...must comply with national wiring standards and it must be ordered separately as it is not part of the standard Exodraft scope of delivery Checking and changing rotation of impeller To check the rotati...

Страница 20: ...t be subjected to misalignment in shipping or during installation Apply power and check that the impeller is rotating in the direction of the arrow on the side of the motor housing All Exodraft CFIR f...

Страница 21: ...ion Remove the sixteen hex nuts holding the motor mounting plate to the housing Motor and impeller assembly can be lifted out of the housing See table listing weights for each model Clean the impeller...

Страница 22: ...22 UK Your energy Optimized Disassembly and assembly of motor section Vertical direction 1 ttes med h nd 2 Motor unit st ttes med h nd 3...

Страница 23: ...UK 23 3112009_CFIR_UK Horizontal direction 1 Motor unit underst ttes med h nd Motor unit underst ttes med h nd 2 Motor unit underst ttes med h nd 3...

Страница 24: ...gn matter is stuck in the impeller A ball bearing is damaged A balancing weight has fallen off impeller Remove the transportation device Turn off the fan and remove the foreign matter Turn the fan off...

Страница 25: ...factured in conformity with the provisions of the following regulations The Supply of Machinery Safety Regulations 2008 Electrical Equipment Safety Regulations 2016 Electromagnetic Compatibility Regul...

Страница 26: ...ion verensst mmer med f ljande standard er Jota t m selvitys koskee on seuraavien standardien mukainen Sem eru me talin i sta festingu Pessari eru i fullu samr mi vi eftirtalda sta la Sono stati fabbr...

Страница 27: ......

Страница 28: ...o exodraft no www exodraft no UK Exodraft Ltd 24 Janes Meadow Tarleton GB Preston PR4 6ND Tel 44 0 1494 465 166 Fax 44 0 1494 465 163 info exodraft co uk www exodraft co uk DE Exodraft a s Niederlassu...

Отзывы: