background image

1.

Check the voltage of the battery with a digital
voltmeter. Locate the voltage reading of the battery
in the table below and charge the battery for the
recommended time interval to bring the charge up
to a full charge of 12.6 volts or greater.

Important:

Make sure the negative battery

cable is disconnected and the battery charger
used for charging the battery should have
an output of 16 volts and 7 amps or less to
avoid damaging the battery (see chart for
recommended charger settings). This is
especially important on Kohler EFI (Electronic
Fuel Injection) units. Failure to do so may
damage the ECU (Electronic Control Unit).

Voltage
Reading

Percent
Charge

Maximum
Charger
Settings

Charging
Interval

12.6 or
greater

100%

16 volts/7
amps

No Charging
Required

12.4 – 12.6

75–100%

16 volts/7
amps

30 Minutes

12.2 – 12.4

50–75%

16 volts/7
amps

1 Hour

12.0–12.2

25–50%

14.4 volts/4
amps

2 Hours

11.7–12.0

0–25%

14.4 volts/4
amps

3 Hours

11.7 or less

0%

14.4 volts/2
amps

6 Hours or
More

CAUTION

If the ignition is in the “ON” position there
is potential for sparks and engagement of
components. Sparks could cause an explosion or
moving parts could accidentally engage causing
personal injury.

Be sure ignition switch is in the “OFF” position
before charging the battery.

2.

Connect the negative battery cable.

Note:

If the positive cable is also disconnected,

connect the

positive (red) cable

to the positive

battery terminal

first

, then the negative (black) cable

to the negative battery terminal. Slip insulator boot
over the positive terminal.

Note:

If time does not permit charging the battery,

or if charging equipment is not available, connect
the negative battery cable and run the vehicle
continuously for 20 to 30 minutes to sufficiently
charge the battery.

Servicing the Engine

The engine is shipped with oil; check oil level and if
necessary fill to the appropriate level. Exmark 4-Cycle
Premium Engine Oil is recommended; refer to the
Engine Owner's manual for an appropriate API rating
and viscosity.

Servicing the Hydraulic Oil

The machine is shipped with hydraulic oil in the
reservoir.

1.

Run the machine for approximately 15 minutes to
allow any extra air to purge out of the hydraulic
system.

2.

Check hydraulic reservoir and if necessary fill the
reservoir to the appropriate level with Exmark
Premium Hydro oil (see the Operator’s manual).

3.

Replace hydraulic reservoir cap and tighten until
snug.

Do Not overtighten.

Filling Out the Product
Registration

Fill out the online warranty registration form.

2

 

Отзывы: