Maintenance
7. Before installing the new filters, apply a thin coat
of Exmark Premium Hydro oil on the surface of
the two rubber seals.
8. Install the new filters and torque to 14 ft-lb (19
N-m).
9. Fill the hydraulic system as stated in
Check
Hydraulic Oil Level
section.
Exmark Premium Hydro Oil is recommended.
Refer to the chart for an acceptable alternative:
Hydro Oil
Change Interval
Exmark Premium Hydro
Oil (Preferred)
500 Hours
Mobil 1 15W50
250 Hours
10. Remove the catch pan and properly dispose of
hydro oil and filter according to local codes.
11. Re-install the pump drive belt.
12. Start engine and move throttle control ahead to
full throttle position. Move the speed control
levers to the full speed and run for one minute.
Shut down the machine, allow the hydros to cool
and recheck oil level.
13. Remove the jack stands.
Note:
Do Not change the hydraulic system oil
(except for what can be drained when changing filter),
unless it is felt the oil has been contaminated or been
extremely hot.
Changing oil unnecessarily could damage hydraulic
system by introducing contaminants into the system.
Wheel Hub - Slotted Nut
Torque Specification
Service Interval: After the first 100 hours
Every 500 hours thereafter
When tightening the slotted nut on the wheel motor
tapered shaft:
1. Remove and discard the cotter pin.
2. Torque the slotted nut to 200 ft-lb (271 N-m).
3. Check distance from bottom of slot in nut to
inside edge of hole. Two threads (0.1 inch) or less
should be showing.
Figure 24
1.
0.1 inch max
2.
No more than two
threads (0.1 inch max)
should be showing here.
4. If more than two threads (0.1 inch) are showing
remove nut and install washer (P/N 1-523157)
between hub and nut.
5. Torque the slotted nut to 200 ft-lb (271 N-m).
6. Then tighten nut until the next set of slots line up
with the cross hole in shaft. Do Not loosen nut
to align the slot. If required, tighten to the next
set of slots.
7. Install new cotter pin (P/N 1-806800).
Note:
Do Not use anti-seize on wheel hub.
Check Spark Arrester
(if equipped)
Service Interval: Every 50 hours
WARNING
Hot exhaust system components may ignite
gasoline vapors even after the engine is
stopped. Hot particles exhausted during
engine operation may ignite flammable
materials. Fire may result in personal injury
or property damage.
Do Not refuel or run engine unless spark
arrester is installed.
1. Stop engine, wait for all moving parts to stop, and
remove key. Engage parking brake.
2. Wait for muffler to cool.
35
Содержание 000 & Higher
Страница 1: ...LAZER Z MODELS For Serial Nos 790 000 Higher Part No 4500 471 Rev A...
Страница 11: ...Safety 107 2102 107 2112 109 3148 109 7232 1 Fast 3 Neutral 2 Slow 4 Reverse 109 7330 109 7929 11...
Страница 49: ...Schematics Hydraulic Diagram 49...
Страница 51: ...Notes 51...
Страница 52: ...Notes 52...
Страница 53: ...Service Record Date Description of Work Done Service Done By 53...
Страница 54: ...54...
Страница 55: ...55...