Test Functions
620
88000 Series
40/100/200/400G Advanced - Lanes Mapping & Skew
Default/Random/Manual Mapping
Allows changing the PCS/Logical lane mapping that will be used for the
test. Not available with 100 GbE client in OTU4.
Default Mapping
sets the TX mapping to the default numerical order
value which corresponds to the ascending PCS/Logical lane order.
Random Mapping
sets the TX mapping in a random order. Each time
the button is tapped, random alignment markers are assigned to each
PCS/Logical lane.
Manual Mapping
allows setting the TX mapping manually.
PCS/Logical Lane/Lane Marker
and
Assigned Status
:
The
PCS/Logical Lane/Lane Marker
buttons allow assigning the
corresponding Lane Marker to the selected PCS/Logical or
xGAUI-y/CAUI/XLAUI/Physical Lane mapping (the one pointed by
the arrow). The
Assigned Status
column displays a check mark
next to the assigned PCS/Logical Lanes. Range is from
0
to
15
for
400G,
0
to
7
for 200G,
0
to
19
for OTU4/100G, and
0
to
3
for
OTU3/OTU3e1/OTU3e2/40G.
PCS/Logical Lane
and xGAUI-y/
CAUI/XLAUI/Physical Lane
columns indicate the target PCS/Logical to
xGAUI-y/CAUI/XLAUI/Physical mapping.
Clear All
clears the PCS/Logical to xGAUI-y/CAUI /XLAUI/Physical
Lane assignments.
OK
accepts the new PCS/Logical to xGAUI-y/CAUI/XLAUI/Physical
lane mapping. All target PCS/Logical Lane fields must contain an
assignation, including duplicates, to give access to the
OK
button.
Note:
A PCS/Logical Lane marker can be assigned more than once. If this is the
case, a red background is used to highlight all occurrences of this
PCS/Logical Lane marker.
Содержание Power Blazer 88200NGE
Страница 1: ...www EXFO com User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE...
Страница 14: ......
Страница 20: ......
Страница 64: ...Test Setup Test Applications 54 88000 Series OTN BERT...
Страница 65: ...Test Setup Test Applications Power Blazer 55 OTN BERT OTU4 for 88200NGE 890 890NGE OTU4 for 88260...
Страница 71: ...Test Setup Test Applications Power Blazer 61 SONET SDH BERT For SDH BERT...
Страница 76: ...Test Setup Test Applications 66 88000 Series SONET SDH DSn PDH BERT For SDH...
Страница 620: ......
Страница 726: ......
Страница 752: ......
Страница 756: ......
Страница 768: ......
Страница 789: ...Glossary Power Blazer 779 10G Ethernet Client The following figure presents a typical network application...
Страница 803: ...Glossary Power Blazer 793 Ethernet Cables Straight Through Cable 1000 Mbit s Crossover Cable 1000 Mbit s...
Страница 847: ...Glossary Power Blazer 837 SONET DSn SDH PDH The GUI Grid indicates the TUG 2 x and TUG 3 x values...
Страница 886: ...0 5 1 5 48 5 0 176 W d y K y K D...