Test Setup - Test Configurator, Timer, and System
362
88000 Series
SyncE
Pass/Fail Verdict
check box when selected (default) enables the use
of the pass/fail verdict. The global pass/fail verdict is based on the
following criteria:
ESMC Rate Threshold
(when enabled),
QL
Mismatch Monitoring
(when enabled),
ESMC Loss
, or
Link Down
.
ESMC Rate Threshold
check box when selected (default) enables the
ESMC rate threshold monitoring which will declare a Fail verdict when
the ESMC frame rate is outside the range of 0.8 to 10.2 frames/s.
ESMC Generation
Generated QL
The
Generated QL
check box when selected (default) enables the
generation of the selected QL message.
The
Generated QL
field allows the selection of the QL message that
will be generated. See page 512 for the list of QL message (default is
QL-EEC2/ST3
).
Note:
For 1GE Electrical interface using
Local Clock
set to
Slave
, the
Generated
QL
is not configurable and is set to
QL-DNU/DUS
with its check box
selected.
QL Rate (frame/s)
defines the frame rate at which the ESMC transmit
the QL message value:
1
(default),
5
, or
10
frames per second. For 1GE
Electrical interface using
Local Clock
set to
Slave
, the
QL Rate
is not
configurable and is set to
1
frame/s.
Restore SyncE Defaults
Reverts the SyncE test application to its default factory settings.
Содержание Power Blazer 88200NGE
Страница 1: ...www EXFO com User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE...
Страница 14: ......
Страница 20: ......
Страница 64: ...Test Setup Test Applications 54 88000 Series OTN BERT...
Страница 65: ...Test Setup Test Applications Power Blazer 55 OTN BERT OTU4 for 88200NGE 890 890NGE OTU4 for 88260...
Страница 71: ...Test Setup Test Applications Power Blazer 61 SONET SDH BERT For SDH BERT...
Страница 76: ...Test Setup Test Applications 66 88000 Series SONET SDH DSn PDH BERT For SDH...
Страница 620: ......
Страница 726: ......
Страница 752: ......
Страница 756: ......
Страница 768: ......
Страница 789: ...Glossary Power Blazer 779 10G Ethernet Client The following figure presents a typical network application...
Страница 803: ...Glossary Power Blazer 793 Ethernet Cables Straight Through Cable 1000 Mbit s Crossover Cable 1000 Mbit s...
Страница 847: ...Glossary Power Blazer 837 SONET DSn SDH PDH The GUI Grid indicates the TUG 2 x and TUG 3 x values...
Страница 886: ...0 5 1 5 48 5 0 176 W d y K y K D...