EXFO FLS-100 Скачать руководство пользователя страница 8

Description

3

2 Description

The FLS-110 Optical Polarized Source is a fiber-optic source used with a power 
meter to measure power and loss in singlemode fibers, and with a PMD analyzer 
such as the FTB-5500 and FTB-5500B for PMD measurements. The unit includes a 
LED optical source and a 2 kHz signal generation for fiber identification. The FLS-110 
is powered by either the built-in rechargeable NiCd battery pack, the 9 V alkaline 
battery, or the AC adapter/charger.

LED Status Indicators

Keypad

Connector Panel

Low NiCd battery pack

AC adapter/charger operation 

(blinks when auto-off is activated*)

NiCd battery operation 

(blinks when auto-off 

is activated*)

9 V battery operation (blinks 

when auto-off is activated*)

AC

9V

NiCd

LOW

BAT

SUPPLY

low

high

LEVEL

* Unit powers off after 10 minutes of inactivity

Low output power

source active (lights

up in CW mode,

blinks in 2 kHz mode)

High output power

source active (lights

up in CW mode,

blinks in 2 kHz mode)

low

high

CW

on / off

Powers unit on or off

(high output power and

CW mode by default)

Selects low output 

power
Selects high output 

power

auto

2 kHz

off

Activates continuous

wave (CW) signal

Activates and

deactivates auto-off

Activates (2 kHz) 

modulated signal

AC adapter/charger input

Optical port

Содержание FLS-100

Страница 1: ...USER GUIDE OPTICAL POLARIZED SOURCE FLS 110 NETWORK TESTING...

Страница 2: ...EXFO for its use nor for any infringements of patents or other rights of third parties that may result from its use No license is granted by implication or otherwise under any patent rights of EXFO EX...

Страница 3: ...leaning the Optical Port 4 Recharging the NiCd Battery Pack 4 Replacing the 9 V Alkaline Battery 5 Periodic Source Verification 5 4 Troubleshooting 6 Finding Information on the EXFO Web Site 6 Contact...

Страница 4: ...e or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different fr...

Страница 5: ...easurement Control and Laboratory Use Part 1 General Requirements EN 60825 1 1994 Safety of LED products Part 1 Equipment classifications requirements and user s guide EN 55011 1993 Limits and methods...

Страница 6: ...diately Conventions Before using the product described in this manual you should understand the following conventions WARNING Indicates a potentially hazardous situation which if not avoided could res...

Страница 7: ...pliance with standard IEC 60825 1 Amendment 2 2001 Laser radiation may be encountered at the output port The following label indicates that a product contains a Class 1 source Note Label shown for inf...

Страница 8: ...battery pack AC adapter charger operation blinks when auto off is activated NiCd battery operation blinks when auto off is activated 9 V battery operation blinks when auto off is activated AC 9V NiCd...

Страница 9: ...l port when not in use Clean the optical port using a lint free swab dipped in isopropyl alcohol 98 pure or more and blow dry with compressed air In case the unit is equipped with a universal interfac...

Страница 10: ...EXFO will cover costs related to the collection treatment recovery and disposal of end of lifecycle waste generated by electronic equipment introduced after August 13 2005 to an European Union member...

Страница 11: ...on screen instructions You will be given a list of questions pertaining to your subject The EXFO Web site also provides the product s most recent technical specifications Problem Possible Cause Solut...

Страница 12: ...rtation Maintain a temperature range within specifications when transporting the unit Transportation damage can occur from improper handling The following steps are recommended to minimize the possibi...

Страница 13: ...ING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IN NO EVENT SHALL EXFO BE LIABLE FOR SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES Liability EXFO sh...

Страница 14: ...FO products are not covered by this warranty This warranty excludes failure resulting from improper use or installation normal wear and tear accident abuse neglect fire water lightning or other acts o...

Страница 15: ...ich it was observed 5 Return the equipment prepaid to the address given to you by support personnel Be sure to write the RMA number on the shipping slip EXFO will refuse and return any package that do...

Страница 16: ...1 418 683 5498 Fax 1 418 683 9224 quebec service exfo com EXFO Europe Service Center Omega Enterprise Park Electron Way Chandlers Ford Hampshire S053 4SE ENGLAND Tel 44 2380 246810 Fax 44 2380 246801...

Страница 17: ...obtain this product s most recent technical specifications visit the EXFO Web site at www exfo com NOTE a At 23 C 2 C THIS PRODUCT COMPLIES WITH 21 CFR 1040 1 AND 1040 11 AND WITH IEC 60825 1 1993 A1...

Страница 18: ...8 683 0211 Fax 1 418 683 2170 EXFO AMERICA 3701 Plano Parkway Suite 160 Plano TX 75075 USA Tel 1 972 907 1505 Fax 1 972 836 0164 EXFO EUROPE Omega Enterprise Park Electron Way Chandlers Ford Hampshire...

Отзывы: