Страница 1: ...EXERGEN 400 Pleasant Street Watertown MA 02472 Phone 617 923 9900 Fax 617 923 9911 www exergen com e mail industrial exergen com DX SERIES Handheld Infrared Thermometers User s Guide...

Страница 2: ......

Страница 3: ...perature Measurements 5 2 5 1 General Operation 5 2 6 SCAN Mode Temperature Measurements 6 2 6 1 General Operation 6 Chapter Three Measurement Tips 6 3 1 Optimizing Target Area Measurements 6 3 2 Meas...

Страница 4: ...e quality instrument calibration programs Operate the DX in SCAN mode for thermal scanning measurements over a range of tar get temperatures Thermal Scanning is very useful in many applica tions such...

Страница 5: ...00 F 86 to 871 C Unit includes a Remote Sensor 9 V DC Alkaline Battery and DX Instruction Manual Chapter Two Operation 2 1 DX Controls LED Display MEASUREMENT button LED Display Sensor Window AECS Cup...

Страница 6: ...ding the push button in turn the unit on with the MEASURE MENT button The instrument now reads in C instead of F To return to the original setting simply repeat the process 2 3 To Change Mode of Opera...

Страница 7: ...the button If the target is electrical equipment Exergen manufactures the Model E Microscanner instruments for safe and convenient inspection of electrical equipment Contact Exergen for more informat...

Страница 8: ...get is large The DX is a wide angle thermal scanner with a fixed emissivity of 0 9 The target s temperature is continuous ly displayed and updated 10 times per second for as long as you hold the MEASU...

Страница 9: ...se the following procedure 1 Determine the appropriate measurement distance from your desired target 2 Make sure the MODE switch is on SCAN 3 Point the nosepiece at the target 4 Press and hold the MEA...

Страница 10: ...Measurements for NIST Traceablity If you look at the DX s nosepiece you will see that it is really a small reflective cup with the sensor s window at its base When the DX s nosepiece touches the surf...

Страница 11: ...higher than 32 F 0 C because the instrument actually measures the air condensing on the ice a reac tion that generates a small amount of heat As long as the ice is not melting the DX will accurately r...

Страница 12: ...eadings If either the target s tempera ture or the unit s ambient temperature exceeds the operational limits the display will default to an error message The battery voltage is also monitored A low ba...

Страница 13: ...ion Error Code Remedy Measurement Fault High Ambient Temperature HI A Ambient 122 F 50 C Move to alternate location Low Ambient Temperature LO A Ambient 32 F 0 C Move to alternate location Low Battery...

Страница 14: ...ent Was the instrument s nosepiece in contact with the surface Touch the nosepiece flush to the target s surface and repeat the measurement If after applying all of the above solutions the instrument...

Страница 15: ...even Warranty Exergen warrants the DX to be free of defects in material and workman ship for a period of one year from the date of purchase and will repair or replace the returned instrument at no cha...

Страница 16: ...EXERGEN C O R P O R A T I O N 400 Pleasant Street Watertown MA 02472 617 923 9900 FAX 617 923 9911 818526 Rev 3...