IDx User´s Manual
Exemys
Technical Specifications
Power Supply
10-30 Vdc, internal switching power source.
Operating current
100mA max.
Relay
0.5ª 120Vca, 1ª 24Vdc, 0.3ª 60Vdc.
Optoisolators
Optoisolated output, 30V max, 10mA max.
Transistor
Transistor output, 30V max, 100mA max.
TTL
Digital output TTL (0-5V)
Protections
Varistors in power supply and relay outputs. Lightning protection and ground
terminators. Loop input isolation with transformer.
Inductance range
20uHy a 2000uHy. Factor Q>5
Frequency range
25Khz a 120Khz
Presence time
1hour for
δ
L/L = 3%
Sensibility
δ
L/L = 0.02%, 0.05%, 0.1%, 0.5%
Mux time
10mS
Enclosure
Polycarbonate (top) y Noril (base), UL94-V0, Grey RAL 7035.
Factory Configuration
ON
LOW
MEDIUM
HIGH
VERY HIGH
SENS. CH 1
SENS. CH 2
FRECUENCY
PRESENCE
ON
8
7
6
5
4
2
1
Figure 9 – Factory Configuration
www.exemys.com
Rev. 4.0.1
Página 13