![EXELAIR EX1603KIT Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/exelair/ex1603kit/ex1603kit_operators-manual_2449762009.webp)
1/2" AIR IMPACT WRENCH
G
F
C
OPERATION
Forward/Reverse rotation is selected by pushing
the F/R valve stem in the direction shown by the
arrow on the housing of the wrench.
1. How to install/tighten threaded fasteners
Push the F/R valve stem (F) forward as
indicated by "F" marked on the housing.
Press the trigger (C). Then the tool anvil (B)
runs clockwise. (See Figure 7)
2. How to remove/loosen threaded fasteners
Push the F/R valve stem (F) backward as
indicated by "R" marked on the housing.
Press the trigger (C). Then the tool anvil (B)
runs counterclockwise. (See Figure 8)
7
8
9
NOTE:
This tool features a power
regulator valve. Press the air
regulating knob (D) downward and
then slowly turn it either clockwise or
counterclockwise to have either of 4
settings pointing at the triangle mark
on the housing. The settings 1, 2, 3,
4 are only for reference and do not
denote a specific power output.
"Setting 1" is the least amount of
power while "Setting 4" is most
amount of power.
NOTE:
This tool also features a
grease cap (G) on the tool body.
Remove the screw in the grease cap
with a hex key (not provided). Use a
grease gun (not included) and insert
the gun nozzle into the grease cap.
Several drops of grease are
recommended for lubrication. After
lubrication, replace the screw secure
and tight. This will protect the rotor
gears of motor assembly in good
working condition and extend tool life.
Lubricate the rotor gears once every working day. (See Figure 9)
F
C
8