![EXE RISE D8 Скачать руководство пользователя страница 44](http://html.mh-extra.com/html/exe-rise/d8/d8_user-and-service-manual_2449737044.webp)
44 / 64
4.4 ELECTRICAL CONNECTIONS
Before connecting the hoist to the power supply, check that voltage and power of the electric supply
corresponds to those reported on the chain hoist plate. Check also that the earthing system is efficient.
Do not insert the plug of the hoist directly into a power socket. Only use a dedicated chain hoist controller.
Installers must equip the branch circuit with a grounding system, protection against current overloads and
short circuits that comply with the requirements of the laws on safety and health protection on work place of
the Country where the hoist is installed.
In order to avoid risk of electrocution and malfunction, check that all cables powering the hoist are protected
against possible external damages.
EXE Rise chain hoists are available in both direct and low voltage control. They must be connected to a
power and control system that is suitably designed to operate the chain hoists and handle the power
consumption of the motor.
EXE Rise hoists are factory set to be run with a voltage of 400 V AC. The DC hoist is fitted with a CEE 16A
6h 400VAC
– 3PH +G black plug. plug as standard. The LVC hoist comes with a CEE 16A 4h 110VAC -
3PH +G black socket.
Electrotechnical adjustments may only be performed by authorised specialists.
EXE Rise hoists are manufactured to be run with a voltage of 400 V AC. The DC hoist is fitted with a CEE
16A 6h 400VAC
– 3PH +G black or red plug. plug as standard with IP RATE 67. The wiring must be done
according to the standard sequence following:
Low Voltage Control
Direct Control
PIN
COLOR
L1
Brown
L2
Black
L3
Grey
PE
Yellow
– Green
Table 18: “Plug wiring”
The LVC hoist comes with a CEE 16A 4h 110VAC - 3PH +G black or yellow socket, with IP RATE 67.
The wiring must be done according to the standard sequence following:
PIN
COLOR
FUNCTION
L1
Brown
Up
L2
Grey
Down
L3
Black
Common 24 VAC
PE
Yellow
– Green
Earth
Table 19: “Socket wiring”
PIN
COLOR
L1
Grey
L2
Black
L3
Brown
PE
Yellow
– Green