• Low inrush current

• Conducted EMI meets EN 55022 Level B

• AC Fail status signal

• Output sequencing capability

• Global shutdown capability

• Overcurrent protection standard on all outputs.

• Overvoltage protection on all outputs

• Over temperature limiting on all 

powerMods

and 

PowerPacs

• Safety Agency Approvals: CE Mark, UL, CSA

• DC OK (Power Good) status signal (consult datasheet) 

• Wide output voltage adjustment range

• RoHS compliant

Optional Features

• Reversed fan airflow direction

• Conformal coating

• Low leakage current

Section 4.2

Installation Considerations

The  UltiMod  series  models  may  be  mounted  on  any  of  three

surfaces using standard M4 screws. The chassis comes with four

mounting points on the base. Maximum allowable torque is 2Nm.

The  maximum  penetration  depth  is  6mm.  Additionally,  the

fleximount

TM

system on both side walls of the

powerPac

chassis

facilitates flexible mounting. 

When  selecting  a  mounting  location  and  orientation,  the  unit

should  be  positioned  so  air  flow  is  not  restricted.  Maintain  a

50mm minimum clearance at both ends of the UltiMod power

supply  and  route  all  cables  so  airflow  is  not  obstructed.  The

standard unit draws air in on the input side and exhausts air out

the load side. If airflow ducting is used, avoid sharp turns that

could create back pressure. 

Avoid excessive bending of output power cables after they are

connected to the UltiMod 

powerMod

s. For high current outputs,

use  cable-ties  to  support  heavy  cables  and  minimise

mechanical stress on output studs. Be careful not to short-out to

neighboring  output  studs.    UltiMod 

powerMod

s  are  supplied

with spring washers on all output screws. These (or equivalents)

should be used and thread locking compounds are not required.

The  maximum  torque  recommended  on  output  connectors  is

4Nm.    Avoid  applications  in  which  the  unit  is  exposed  to

excessive  shock  or  vibration  levels  that  exceed  the  specified

levels.  In  such  applications,  a  shock  absorption  mounting

design is required.

Section 4.3

UltiMod Mounting Considerations

Always fill all output slots of the UltiMod. If a slot is not filled

with a 

powerMod

, it should be filled with an Empty Slot Cover

(part  numbers  XB1,  XB2  or  XB3).  Empty  Slot  covers  are

plastic assemblies whose main function is to fill up an empty

slot.  Excessive  airflow  escape  from  an  empty  slot  may

degrade thermal performance and result in overheating and

damage to the UltiMod unit. Refer to Section 4.11 for optimum

positioning of 

powerMods

•  Do  not  unplug 

powerMod

s  while  input  power  is  applied  to  the

powerPac

. The UltiMod is not designed for hot-plug applications.

•  Do not restrict airflow to the unit. The cooling fan draws air

into the unit and forces it out at the output terminals.

•  Always ensure that output screws are properly torqued before

UltiMod Designer Manual   

De

sig

ne

r M

an

ua

l

www.excelsys.com

2

DESIGNERS’ MANUAL

This  UltiMod  Designers’  Manual  has  been  prepared  by

Excelsys  experts  to  assist  qualified  engineers  and

technicians  in  understanding  the  correct  system  design

practices  necessary  to  achieve  maximum  versatility  and

performance from any of the Ultimod products.

Section 4.1

Overview of UltiMod

The  UltiMod  series  allows  users  to  instantly  configure  high

efficiency, off-line power supplies. Although very small in size,

(40.4mm high, 260mm long and either 89mm or 127mm wide)

the  UltiMod  provides  up  to  1200W  of  output  power. The UX4

delivers  up  to  600W  and  can  be  populated  with  up  to  4

powerMods

, the UX6 delivers up to 1200W and can be populated

with up to 6 

powerMods

.    

A  complete  power  supply  is  configured  by  selecting  and

inserting up to six DC output modules called 

powerMods

to build

a power supply that offers the advantages of a custom supply,

but  is  assembled  from  standard  and  modular  building  blocks

continuing  the  Excelsys  tradition  of  industry  leading

configurable power supplies.

Manufactured in world class power supply facilities, the UltiMod

is completely user configurable. If output requirements change,

i.e.  more  power  or  a  different  output  voltage  is  needed,

upgrading is easy: simply unlock a single screw and replace

the slide-in 

powerMod 

assembly with the preferred alternative.

Allowing additional flexibility, 

powerMods

can be connected in

parallel  to  increase  output  power,  or  in  series  for  higher

voltages (subject to staying within isolation ratings and giving

due consideration to any SELV requirements).

A  user-friendly  interface  on  connector  J3  of  each 

powerMod

provides control and output sequencing capability, in addition to

useful status indicators. Please consult our Excelsys applications

team if you have other special requirements. 

The plug-together architecture facilitates ‘instant’ custom power

solutions with industry leading 17W/in

3

power density and up to

92%  conversion  efficiency.  The  series  is  designed  for  highest

efficiencies and consists of two Input AC front ends (

powerPacs)

,

UX4 and UX6 and 11 DC output 

powerMods 

(XgA to XgL).  

Standard Features

• Input Voltage: 85V to 264Vac 47 to 63 Hz

• Outputs: Up to 12 isolated outputs

• Full power output to 40°C; Derating to 70°C

Содержание ultimod

Страница 1: ...Designer Manual...

Страница 2: ...um positioning of powerMods Do not unplug powerMods while input power is applied to the powerPac The UltiMod is not designed for hot plug applications Do not restrict airflow to the unit The cooling f...

Страница 3: ...ts Conversion in the output assemblies is achieved by the most advanced high efficiency converters resulting in reduced UltiMod Designer Manual Designer Manual www excelsys com 3 size for magnetics an...

Страница 4: ...meeting the unique requirements of individual users The inherent flexibility resulting from modularity concepts is further enhanced by this flexibility Although the products are very versatile care sh...

Страница 5: ...n both Straight line and Foldback modes Straight line Current Limit can be programmed using an external voltage source or resistor potentiometer Connection between the Itrim pin J3 pin4 and the Vout t...

Страница 6: ...alues of R1 to R2 required F 0 0468 for XgH CF 1 042 for XgH Imax 36A for XgH Ilim 20 55 5 less than 85 Imax 36 Example To set the current limit of XgH to 20A determine the external voltage to be appl...

Страница 7: ...ject to not exceeding the maximum module voltage at the output terminals Observe the following precautions when remote sensing 1 Use separate twisted pairs for power and sense wiring 2 Route the sensi...

Страница 8: ...US1 SVT 3100 183 J2 Locking Molex 51110 0850 Non Locking 51110 0860 Crimp Terminal Molex p n 50394 Input Cable Option D The UltiMod Series is also available with an input cable connection option allo...

Страница 9: ...3 pin 5 positive and J3 pin 6 negative on powerMods XgG to XgL Inhibit is available by means of an appropriate signal applied to an opto isolated input on J3 pin7 on XgE on J3 pin 3 and pin 7 on XgF t...

Страница 10: ...t is 2mA Maximum Collector voltage is 30V t7 30ms t8 30ms powerMod LED Indicator The LED indicator on each powerMod module gives a visual indication of the information contained in the Power Good sign...

Страница 11: ...able Using an External Signal A global enable function may be implemented using a signal from the system using the diagram shown This function enables ALL powerMod outputs Temperature Alarm Open colle...

Страница 12: ...ator configure html Section 4 11 powerPac Options Reverse Fan Option 02 The UltiMod is available with reverse air flow direction This is ideal to expel air from the system and works particularly well...

Страница 13: ...pplies are certified to the latest edition as well as the 1st Edition EN60601 1 Medical Devices Directive The 3rd Edition of this standard is published and all Excelsys medically approved power suppli...

Страница 14: ...is not a guarantee of system compliance System EMC performance can be impacted by a number and combination items Design consideration such as PCB layout and tracking cabling arrangements and orientati...

Страница 15: ...he relevant standards HALT Highly Accelerated Life Testing Poor reliability low MTBF frequent field returns high in warranty costs and customer dissatisfaction are often the result of design and or pr...

Отзывы: