5
RULES FOR SAFE INSTALLATION AND OPERATION
All boilers must be installed in accordance
with National, State or Provincial and Local
plumbing, heating and electrical codes and the
regulations of the serving utilities. These codes
and regulations may differ from this instruction
manual. Authorities having jurisdiction should
be consulted before installations are made. In
all cases, reference should be made to the fol-
lowings standards:
USA BOILERS
Current Edition of American National Standard
1.
ANSI/NFPA 31, “Installation of Oil Burning
Equipment”,
for
recommended
installation
practices.
Current Edition of American National Standard
2.
ANSI/NFPA 211 “Chimneys, Fireplaces, Vents
and Solid Fuel Burning Appliances” for venting
requirements.
Current Edition of American Society of Mechanical
3.
Engineers ASME CSD-1, “Controls and Safety
Devices for Automatically Fired Boilers” for
assembly and operations of controls and safety
devices.
All wiring on boilers installed in the USA shall be
4.
made in accordance with the National Electrical
Code and/or local regulations.
CANADIAN BOILERS
Current
Edition
of
Canadian
Standards
1.
Association CSA B139, Installation Code for Oil
Burning Equipment” for recommended installation
practices.
All wiring on boilers installed in Canada shall be
2.
made in accordance with the Canadian Electrical
Code C22.2 and/or local regulations.
The following terms are used throughout this manual
to bring attention to the presence of hazards at various
risk levels, or to important information concerning
product life. These symbols are based on ANSI Z535.6
standard for product literature.
indicates a potentially hazardous situation
which, if not avoided, could result in death, se
-
rious injury or substantial property damage
.
WARNING
!
This boiler has been designed for residential installations. If used for commercial applications, all
jurisdictional requirements must be met. This may require wiring and/or piping modifications. The
manufacturer is not responsible for any changes to the original design.
WARNING
!
indicates an imminently
hazardous situation
which, if not avoided,
will
result in death, se
-
rious injury or substantial property damage.
DANGER
!
do noT store or use gasoline or other flammable vapors or liquids in the vicinity of this or any
other appliance. do noT use gasoline crankcase drainings or any oil containing gasoline.
DANGER
!
Indicates a potentially hazardous situation
which, if not avoided, could result in minor or
moderate injury or property damage.
CAUTION
!
Indicates special instructions on installation,
operation or maintenance which are important
but not related to personal injury hazards.
NOTICE
Содержание DK4EXA075
Страница 38: ...38 ELECTRICAL CONNECTIONS 240007363 Figure 18 Wiring Diagram All Models optional equipment shown...
Страница 41: ...41 Chimney and chimney connections Figure 20 Typical Chimney Locations Figure 19 Proper draft vent locations...
Страница 49: ...49 This page intentionally left blank...