background image

Installation and Operation Manual

Six-inch

HIGH

 Speed PTZ Dome with alarm inputs

Models covered      (ALL 400 series    PTZ400 – PTZ499)

PTZ400 22x HI-SP IVORY   

PTZ405 22x IR HI-SP IVORY 

 

PTZ406 22x IR-HR HI-SP IVORY

PTZ408 18x HI-SP IVORY   

PTZ409 26x HI-SP IVORY   

 

PTZ410 27x HI-SP IVORY

PTZ418 18x HI-SP SILVER   

PTZ420 22x HI-SP SILVER   

 

PTZ425 22x IR HI-SP SILVER

PTZ426 26x HI-SP SILVER   

PTZ428 22x IR-HR HI-SP SILVER 

PTZ430 27x HI-SP SILVER

Version 1.3

For updates to these instructions visit

www.excelPTZ.com

the

excel

PTZ

range

Содержание PTZ400 22x HI-SP IVORY

Страница 1: ...22x IR HI SP IVORY PTZ406 22x IR HR HI SP IVORY PTZ408 18x HI SP IVORY PTZ409 26x HI SP IVORY PTZ410 27x HI SP IVORY PTZ418 18x HI SP SILVER PTZ420 22x HI SP SILVER PTZ425 22x IR HI SP SILVER PTZ426 26x HI SP SILVER PTZ428 22x IR HR HI SP SILVER PTZ430 27x HI SP SILVER Version 1 3 For updates to these instructions visit www excelPTZ com the excelPTZ range ...

Страница 2: ...ng the CCT786 and CCT768 keypad with the excelPTZ series 21 Presets and other functions 22 Patrols Tours How to set them up and use them 23 Auto Scan How to set it up Calling the Auto Scan 26 Record Pattern What is a record pattern 27 What is the difference between a pattern a patrol tour 27 How to set it up Running the Record Pattern 27 Using the Dome s Advanced Functions 29 Using the Advanced Me...

Страница 3: ...cables should be kept way from other high voltage equipment such as mains cables and especially fluorescent lights Using an anti surge protection device is recommended to prevent damage to the domes from lightning and mains surges Damage to domes by lightning or mains voltage surges is not covered under the domes warranty 6 Do not operate in areas exceeding the stipulated limitations concerning te...

Страница 4: ...ring without any blind spots d This dome is a high precision unit and maintains preset positions up to 0 1 3 High Intelligent Settings a This dome can store up to 128 preset positions in non volatile memory that are not lost with a power failure Refer to the section Presets and other functions b The dome can scan horizontally between two points and the scan speed can be modified The dome can scan ...

Страница 5: ...ears on the screen When B W appears on the screen it means that the camera is in black and white mode g AE Mode The setup of Manual Automatic mode 5 Special Dome Features 4 channel alarm input activation single channel alarm output One of the special features of this dome is that it has four in built alarm channels to call four independent presets This means that for example you may have a door co...

Страница 6: ...rve in the comfort of your own premises Overview introduction to fitting PTZ equipment Generally speaking PTZ Domes requires four things 1 They require a power supply and a cable to supply this power to the dome Often external domes are 24V A C but some mini pan and tilt domes are 12V 2 They require a cable to get the video signal back to the monitor or recording device 3 They require a cable to t...

Страница 7: ...s please note DVR s tend to require very good video signals to function correctly and passive baluns can loose some signal strength over the 50 meter mark so try to restrict the use of passive baluns to below 50 meter cable runs when using them with DVRs Above this distance perhaps consider an active balun Active baluns require power passive baluns do not You can mix and match how you wire up your...

Страница 8: ...ds RS485 is a half duplex data transmission type with characteristic impedance of 120 The maximum load capacity is 32 units domes keyboards and DVRs 2 Transmission distances of RS485 Signals using CAT5 or similar cables Selecting a CAT5 or similar sized twisted pair data transmission cable the maximum theoretical transmitting distances are as follows Baud Rate Maximum Transmitting Distance 2400 Bp...

Страница 9: ...tter reliability so the domes function as expected A common mistake installer s make is not making sure the 120 resistor is switched ON in the LAST dome Also installers often select the resistor to ON in another dome in the chain these errors will make control of the dome unpredictable A simplified Daisy chain is shown below This first diagram shows the cables looping in one dome and out of anothe...

Страница 10: ...es you may need to adopt a star configuration for practical purposes For instance all the domes may be so scattered on a large site that running out separate spurs to each dome in a STAR array is the only practical solution So how do you do this in practice The termination resistors must be connected to the two domes that are farthest away from each other such as domes 3 and 5 in the following Sta...

Страница 11: ...signal These are things that you can correct with good installation practices Where you wish to run several separate CAT5 cables out to send the RS485 data signal out to the domes you are in effect correcting the STAR method of RS485 data distribution As previously mentioned the problem with the Star method is that it is not actually designed for RS485 but generally works okay if you follow the pr...

Страница 12: ...e of the PTZ750 RS485 distributor In the following example and diagram domes 1 4 5 and 7 are at the end of each spur and therefore require the 120ohm resistor enabling by moving the jumper setting within the domes Domes 2 3 and 6 are all midway in each spur and do not need the 120ohm resistor and can be left as default The PTZ750 itself has four 120ohm resistors built in as shown and you do not ha...

Страница 13: ...urrent of about 1 25A when the heater is on and you must take this in to consideration when working out maximum cable runs Please note The domes heater doesn t come on until it senses the temperature drops below 0 degrees Celsius At this point the dome will need up to 1 25A 24V A C to operate Please make sure that you have a sufficient power supply and cable installed to cope with this Obviously t...

Страница 14: ... cable the composite cable and the PTZ400 range domes Power cable requirement Assuming a starting voltage of 24V A C is applied at the PSU end Composite cable Heater OFF Heater ON Maximum run 80mtr 70mtr The distances are relatively short due to the high load of the dome when it starts up If the voltage of the dome drops below around 20V A C it will fail to initialize Obviously you can power the d...

Страница 15: ...ad provides the RS485 A and RS485 B connections from the keyboard It is this cable that you would extend using 1 pair of conductors from a CAT5 cable To test the dome on your workbench you can obviously omit the extension cable as the dome and keyboard are next to each other Now connect the RS485 data cable to the breakout box Note that the orange connection is the RS485 A Line connection and the ...

Страница 16: ...r a suitable DVR to control the dome A suitable DVR would be one with PTZ functionality built into it and preferably Pelco D protocol If your DVR has a list of protocols it s always best to try JEC first or Pelco D protocol as these are very widely available In the DVR with either JEC or Pelco D set you must also make sure you set up the baud rate to 2400 JEC protocol is very similar to Pelco D bu...

Страница 17: ...17 24V AC INPUT RS485 A ORANGE RS485 B YELLOW RS485 INPUT ON DVR PSU CAT5 Data cable RG59 Video Cable Power Cable ...

Страница 18: ...quipment they should always be set to PELCO D 2400 baud rate In the diagram this is correct The Jumper on the far right either enables or disables the 120ohm resistor Setting up a unique ADDRESS in a dome SW1 is used to set address of the dome camera from 1 1023 To set the dome address at 1 put switch 1 up To set the dome at address 2 put switch 2 up To set the dome at address 3 put switches 1 2 u...

Страница 19: ...f the Protocol and the Default Baud Rate As shown in Table 2 SW2 is used to set the protocol of communication and the baud rate used by the dome camera DIP 4 to DIP 1 of SW2 is used to select protocols and a maximum of 16 different protocols can be selected The following table shows states of coding switches of protocols selected by the dome camera in which means the protocol has been integrated w...

Страница 20: ... 5 6 Setup of the Baud Rate of Communication As shown in Figure 2 SW2 is used to set the protocol of communication and the baud rate used by the dome camera DIP 6 and DIP 5 of SW2 are used to select the baud rate of communication and 4 different baud rates can be selected in maximum If the controller adopts a non standard baud rate you can adjust it to be identical with that of the controller as p...

Страница 21: ...protocol protocol D or P The current camera address each P T device requires a unique address 1 32 The current baud rate To set up the keyboard to the correct settings for this dome do the following TIP For advanced uses the keyboard also can also adopt the following features these settings are not used for this dome These parameters can all be changed in the following manner To select PROTCOL P e...

Страница 22: ...e camera stays at one location and the speed of travel between each preset point can be set in the menu PRESETS How to set up a preset Aim the dome where you want it to look zoom in or out to get the correct scene and let the camera auto focus Now press the following keys on the keypad xx PRESET where xx is the preset number you wish to store For example 01 PRESET would store PRESET 01 and the cam...

Страница 23: ...hese are called presets An example four preset mini tour Setting the presets using the keypad STEP 1 Using the keypad joystick move to where you wish to start the tour and then press 01 PRESET STEP 2 Now move to the next location and press 02 PRESET STEP 3 Now move to the third location and press 03 PRESET STEP 4 Finally move to where you wish to end the tour and press 04 PRESET Deleting a preset ...

Страница 24: ...isplayed This can be 01 06 In the example we are setting four presets in the first patrol sequence To edit a patrol sequence NO Patrol Item No POS No of Preset Position SP Dome speed 0 1 8 0 and 1 are fastest speed 8 is slowest speed TM Dwell time at this position Time 0 99 seconds SEQ nn The Patrol number 01 06 Special Note The patrol item number NO is an ascending number list of the preset items...

Страница 25: ...e PROGRAM menu Use the joystick pan right movement to enter this menu Now use the Joystick up down direction movement to select RUN PATROL To the right of this is the patrol sequence number xx By moving the Joystick to the right this number can be increased from 1 6 up to six patrols tours can be programmed or decreased using the left direction movement Now press the OPEN button to initiate the pa...

Страница 26: ...start and end positions of the auto scan as above This runs the auto scan function between these two points There are two methods of initiating the auto scan If you enter 97 CALL via the keypad you can initiate the auto scan Note that the 97 CALL will run at the speed set in the RUN AUTO PAN table You may also initiate the auto scan through the Advanced Menu System Enter the Main Menu by selecting...

Страница 27: ...eas only one record pattern can be recorded When a preset is stored the dome stores not only the preset position but also zoom and camera attributes A record pattern does not record zoom attributes A record pattern does not use presets It however allows the user to record a continuous sequence of standard pan and tilt movements or lens commands but does not allow presets flip digital zoom proporti...

Страница 28: ...attern First you must have recorded a record pattern as detailed above This runs a record pattern of up to 40 seconds duration You can run the Record Pattern through the Advanced Menu System Enter the Main Menu by selecting 95 CALL on the keypad You will see the Main Menu displayed on the screen Using the joystick up down direction movement select the PROGRAM menu Use the joystick pan right moveme...

Страница 29: ...tion All these can be configured using the OSD To bring up the camera menu press 95 CALL The OSD is then displayed on the screen You can navigate between the various options using the Joystick control up to increase and down to decrease right pan to enter and left pan to exit You can also use the OPEN button to enter and the CLOSE button to save and exit ...

Страница 30: ... to exit To leave the main menu press EXIT in Main Menu DESCRIPTION OF MENU OPTIONS DISPLAY SETUP To set dome camera address display set position of address set preset title set preset title position open camera screen CAMERA SETUP To set slow shutter set backlight compensation set low light shooting auto manual iris digital zoom auto manual focus white balance CONTROL SETUP To set auto flip alarm...

Страница 31: ...button on the keypad or move the Joystick to the right TITLE DIS ON OFF When this is set to ON the title of the preset point appears in the left of display when the preset is called E g NO 001 ENTRANCE The PROGRAM option is used to setup the title To toggle the settings move the Joystick to the right or press the OPEN button To return to Main Menu use the Joystick down movement to RETURN and press...

Страница 32: ...he settings move the Joystick to the right or press the OPEN button To return to Main Menu use the Joystick down movement to RETURN and press the OPEN button on the keypad or move the Joystick to the right RETURN To return to Main Menu move the Joystick to the left or press the OPEN button ...

Страница 33: ... use the Joystick down movement to RETURN and press the OPEN button on the keypad or move the Joystick to the right ICR SHOT ON AUTO Low light shooting This is used when the external brightness is extremely low Normally the camera works in the automatic state but when the light level falls to below 1 Lux the camera can be switched to the zero luminance state To toggle the settings move the Joystic...

Страница 34: ...ment to RETURN and press the OPEN button on the keypad or move the Joystick to the right WB SET ATW INDOOR OUTDOOR ONEPUSH AUTO MANU Setup of white balance This setting is used when the image produces colour distortion on the screen To toggle this setting move the Joystick to the right ATW automatic trace of white balance INDOOR indoor white balance setting OUTDOOR outdoor white balance setting ON...

Страница 35: ...reeze the image Otherwise set to MOVE to continue running To toggle this setting move the Joystick to the right To return to Main Menu use the Joystick down movement to RETURN and press the OPEN button on the keypad or move the Joystick to the right HOME OPTION enter HOME OPTION sub menu To enter this option move the Joystick to the right The submenu below will be displayed AUTO HOME ON OFF When t...

Страница 36: ... the keypad or move the Joystick to the right DWELL TIME 1 99 This allows the user to set the time period in minutes before returning to HOME when there has been no action To toggle this setting move the Joystick to the right To return to Control Setup use the Joystick down movement to RETURN and press the OPEN button on the keypad or move the Joystick to the right RETURN return to CONTROL SETUP m...

Страница 37: ...ilable MASK REGION This function not available RETURN Return to MAIN MENU MAIN MENU 1 DISPLAY SETUP 2 CAMERA SETUP 3 CONTROL SETUP 4 CAMERA MASK SET 5 PROGRAM 6 PAL CAMERA 7 CAM DEFAULT SET 8 DOME RESET 9 EXIT CAMERA MASK SET MASK PRIVACY MASK SHADE REGION RETURN This function is not available ...

Страница 38: ...ion it will do a 360 scan There are 6 speed selections The first three relate to scans up to 180 and the second three relate to scans greater than 180 The speed is selected using the Joystick pan left or pan right and to initiate the auto scan press the OPEN button SET TITLE To edit titles of preset positions Only 63 preset titles can be edited Select preset point number using the Joystick pan lef...

Страница 39: ...ram stores four preset positions numbers 01 04 However the settable range can be from 1 to 63 and from 65 to 128 You can set up to 16 preset positions per Patrol sequence and you can have up to 6 patrol sequences RUN PATROL To run a multi point patrol select the Sequence Number of the Patrol using the Joystick pan left and pan right and run using the OPEN button Special Note If you notice that som...

Страница 40: ...ight Note that PAL is the UK standard Press the CLOSE button to exit or move down using the up and down toggle to move to the EXIT point MAIN MENU 1 DISPLAY SETUP 2 CAMERA SETUP 3 CONTROL SETUP 4 CAMERA MASK SET 5 PROGRAM 6 PAL CAMERA 7 CAM DEFAULT SET 8 DOME RESET 9 EXIT No sub menu option for this ...

Страница 41: ... settings Press the CLOSE button to exit or move down using the up and down toggle to move to the EXIT point MAIN MENU 1 DISPLAY SETUP 2 CAMERA SETUP 3 CONTROL SETUP 4 CAMERA MASK SET 5 PROGRAM 6 PAL CAMERA 7 CAM DEFAULT SET 8 DOME RESET 9 EXIT No sub menu option for this ...

Страница 42: ...s the DOME settings The following display will be output Use the Joystick left or right pan to toggle between YES and NO Press the CLOSE button to initiate the required option MAIN MENU 1 DISPLAY SETUP 2 CAMERA SETUP 3 CONTROL SETUP 4 CAMERA MASK SET 5 PROGRAM 6 PAL CAMERA 7 CAM DEFAULT SET 8 DOME RESET 9 EXIT ...

Страница 43: ...ddress 1 is set as default in the factory You need to alter the DIP switches within the domes to address 2 3 etc if you have multiple domes on the same site refer to the previous instructions how to set the DIP Switches If you have another dome set at camera address 2 press 2 followed by CAM This would change the screen to CAM 002 And so on MAIN MENU 1 DISPLAY SETUP 2 CAMERA SETUP 3 CONTROL SETUP ...

Страница 44: ... Physical installation of the dome 1 The Style of the Installation 1 Dimension of the Product Figure 3 2 The Style of Installation a Wall Installation Figure 4 b In Ceiling Installation 262 300 7 Figure 5 ...

Страница 45: ...t the dome camera and its attachments 2 Take out the cover of the wall installed bracket see Figure 7 3 Take out system control wires from the bracket see Figure 8 4 Fix the bracket on the wall see Figure 9 Fi gur e 7 Fi gure 8 Fi gure 9 5 Rotate the vitreous cover counterclockwise and take it out see Figure 10 6 Fix the pedestal in the aluminum alloy ball Figure 11 Install the ball on the bracket...

Страница 46: ...ctor D1 into the corresponding socket Take care not to leave wires inside the ball cover but to pull them out of the cover as shown on Figure 15 D1 D1 PIN RS485 VIDEO VIDEO RS485 AC24V AC24V Fi gure 13 Fi gure 14 Fi gure 15 RED CO NNECTO R PO W ER IN BLACK CO NNECTO R RS485 CO NTRO L IN VIDEO O UT RED LINE AC24V I N BLACK LINE AC24V IN O RANGE LINE RS485 YELLO WLINE RS485 10 Insert attachment plug...

Страница 47: ... to restart a tour if necessary D2 connect fan heater AC24V NO O pen col l ect or al arm out put NC Cl ose col l ect or al arm out put COM Com m on col l ect or al ar mout put GND Com m on col l ect or al ar mi nput ALM 1 Channel 1 col l ect or al arm i nput ALM 2 Channel 2 col l ect or al arm i nput ALM 3 Channel 3 col l ect or al arm i nput ALM 4 Channel 4 col l ect or al arm i nput D3 Figure 15...

Страница 48: ... keypad press 30 followed by the Preset button and so on When more than one alarm channel is utilised and activated the dome will respond to each alarm by calling the relevant preset and switching to the next preset after two seconds The dome will lock on to the last alarm activated and will not resume a patrol auto scan or record pattern until the alarm condition is cleared or the HOME option set...

Страница 49: ...n and either a normally open or a normally closed connection Again this is a 0 volt switch and could be used for example to close a circuit to an audible alarm lighting or other warning devices Ensure that the switch line does not carry any voltage Again this switch remains activated until the input alarm s have been cleared reset ALM 2 ALM 1 ALM 3 ALM 4 GND ALM 4 ALM 3 ALM 2 ALM 1 D3 NO NC CO M A...

Страница 50: ...n dome counterclockwise and take it off Note If the Speed Dome Camera is fixed in the aluminum alloy ball you must take off the vitreous cover on the dome Otherwise it will effect picture quality see Figure 16 16 Aligning the MARK on the ball with the notch on the pedestal push the ball upward to the end and rotate clockwise until it clicks into place then mount the vitreous cover by rotating it c...

Страница 51: ...nual Power Supply AC 24V 10 1 25A with fan heater 30 VA with fan heater Power Consumption 15 VA indoor 2 Kg Weight 4 Kg with aluminum alloy ball Installation Indoor ceiling installation or wall mounting Opposite Humidity 10 75 Specifications Environment Temperature 0 40 Pan Speed 0 300 s Tilt Speed 0 120 s Preset 128 presets max Auto Cruise At best 6 cruises Dome Function Pattern 40 sec ...

Страница 52: ...dditional lightning proof equipment must be installed l Always design the installation taking account of the building lightning proof requirements and grounding of outdoor equipment in accordance with the national and industrial standards l The system must be grounded with equal potentials The earth ground connection must satisfy anti interference and electrical safety requirements and must not sh...

Страница 53: ...lean the inner and outer surfaces l For more stubborn contamination use a neutral detergent Any cleanser for high grade furniture is applicable Technical data table Image inductor Colour CCD Pixels Depends on module In phase system In phase inside Video out 1 0Vp p 75 White balance Auto manual Power supply AC24V 10 1 25A Power consumption 30VA including the heater device Weight 4Kg Installation Wa...

Отзывы: