Excell SI-132 Скачать руководство пользователя страница 9

 

                                                                                            

               

 

 
EXCELL PRECISION CO., LTD.     

ZSME300000298 

02005318 

 

1-5 Power Supply 

 

Power Supply Selection 

Model for rechargeable battery: 

1. 6V/5Ah rechargeable battery 

2. Adaptor: Output DC 10V 1A 

Model for alkaline batteries: 

1. Four D size alkaline batteries (purchase by customers) 

Stronly suggest using alkaline batteries, please pay attention to not 
confusing the new and old batteries. 

2. Adaptor: Output DC 10V 1A

 

Power Consumption 

About 32 mA ( Load cell + backlight

single display)                                     

About 37 mA ( Load cell + backlight

double display)                                   

Low Battery Warning

  

 

Please note when the (          ) symbol keeps flashing on the display, the batteries should 
be changed. 

 The scale will turn off automatically after a few hours when the low battery warning 

symbol shows up. The scale must be fully charged, before operating again. 

 

1-6 Error Messages 

    

⇒ 

Initial zero is higher than the zero range when switching the indicator on.  

(Approval models) 

   

⇒ 

Initial zero is lower than the zero range when switching the indicator on. 

(Approval models) 

   

⇒ 

Internal value is unstable. 

   

⇒ 

The weight of the object is over 9 divisions of the maximum capacity. 

   

⇒ 

A/D IC value is over the maximum range. 

 

1-7 Weight Unit 

kg 

1 g  =  0.001 kg 

1 g  =  1 g 

lb 

1 g  =  0.002204623 lb 

lb/oz 

1 g  =  0.03527396 oz 

oz 

1 g  =  0.03527396 oz 

GN 

1 g  =  15.432358 GN 

dwt 

1 g  =  0.6430149 dwt 

ct 

1 g  =  5 ct 

Содержание SI-132

Страница 1: ...ein is the property of Excell Precision Limited and is supplied without liability for errors or omissions No part may be reproduced or used except as authorized by contract or other written permission...

Страница 2: ......

Страница 3: ...Unit 7 Chapter 2 Advanced Functions 8 2 1 Advanced Function Setting Table 8 2 2 Advanced Function Setting Workflow 9 2 3 General Function Setting 10 2 3 1 Automatic Backlight Function Setting 11 2 3...

Страница 4: ...ut extending over the platter edge 5 Please plug the DC JACK before you use water to clean the scale 6 We suggest using wet cloth to clean the bottom of the scale 7 Please operate or charge the scale...

Страница 5: ...3 Do not short the battery terminals to check whether there is current Please check whether the connection point is firm to guarantee good connection 4 The battery should be replaced by specialized pe...

Страница 6: ...KEY This key possesses two functions Power On and Zero function OFF KEY When the scale is switched on press the OFF key the scale will switch off TARE KEY The tare function will not operate during the...

Страница 7: ...the screen displays the net weight value of the goods 3 Remove the full container the screen displays the negative weight value of the container At this time pressing the TARE key again will cancel th...

Страница 8: ...ERO key Wait till display shows to enter Self Test Mode Press UNITS key Press ON ZERO key Press ON ZERO key Press ON ZERO key Press ON ZERO key Press UNITS key Press UNITS key Press UNITS key INTERNAL...

Страница 9: ...ease note when the symbol keeps flashing on the display the batteries should be changed The scale will turn off automatically after a few hours when the low battery warning symbol shows up The scale m...

Страница 10: ...sections DISPLAY LEVEL 1 FUNCTION DISPLAY LEVEL 2 FUNCTIONS Exit the ADVANCED FUNCTION setting mode General Function setting mode Return to the ADVANCED FUNCTION setting menu Automatic backlight funct...

Страница 11: ...Function setting mode The LCD shows Overall workflow of the Advanced Function setting mode Press UNITS key Press ON ZERO key Press UNITS key Press UNITS key Press ON ZERO key Press ON ZERO key General...

Страница 12: ...c Power off Timer Settings Hi Lo OK Settings Restore the Default Settings Noise Filter Settings Hold Function Settings Auto Unit Weight Averaging Setting Refer to the following sections for detailed o...

Страница 13: ...st status Automatic backlight function When the weight is over 10d the display backlight will be on After the weight is stable for 10 seconds or when the scale returns to zero the display backlight sw...

Страница 14: ...from 0 to 9 UNITS key Downward key from 9 to 0 TARE key Move the cursor to right NET GROSS key Move thecursorto left Automatic power off timer setting Use ON ZERO or UNITS key to key in parameter 0 N...

Страница 15: ...a b c The definition of a b c positions a 1 beep sound on 0 beep sound off b 1 beep sound on when stable 0 beep sound on when unstable c 1 beep sound on when the weight is between high and low limits...

Страница 16: ...xternal 4 Sampling setting for the counting function Setting is not available for approval models ACTIONS DISPLAY NOTE Return Cancel the restoration Restore to the default setting ON ZERO key Upward k...

Страница 17: ...last parameter setting Filter parameter setting Use ON ZERO or UNITS keys to key in the parameters Default setting 5 Parameter 0 9 the larger the number the faster the filter response Fast response c...

Страница 18: ...ws the current weight value When the weight returns to zero 10d the hold mode is cancelled automatically DISPLAY ACTIONS NOTE Hold function setting Use ON ZERO or UNITS keys to key in the parameters D...

Страница 19: ...e parameters Default setting 0 0 Auto unit weight averaging 1 Non auto unit weight averaging ON ZERO key Upward key from 0 to 9 UNITS key Downward key from 9 to 0 TARE key Move the cursor to right NET...

Страница 20: ...he maximum capacity of 1st unit and the unit The digit on the right side keeps flashing The scale is calculating the internal value of the zero point After stabilization the LCD shows the calibration...

Страница 21: ...CO LTD ZSME300000298 02005318 Appendix 1 7 Segment Display Characters Digit 7 segments letter Alphabet 7 segments letter Alphabet 7 segments letter 0 A N 1 B O 2 C P 3 D Q 4 E R 5 F S 6 G T 7 H U 8 I...

Отзывы: