Press
UNIT
key
Press
UNIT
key
1-7 Self-Test Mode
When power is off, hold NET/GROSS and press ON/ZERO key, Wait till display shows
to enter “Self-Test Mode”
.
INTERNAL VALUE MODE
(must hook up full-bridge Load Cell to test)
Press TARE / PT to enter, and the display shows internal value
Put on the weight and check whether the internal value has obvious change.
Press ON/ZERO key to back to the last screen , the display shows
KEYPAD TEST MODE
Press TARE/ PT to enter, display shows
Keypad’s internal code: TARE/ PT key= 03 , UNIT key= 05, NET/GROSS key=06,
MC key = 04 , M+ key=02
Press ON/ZERO key to back to the last screen , the display shows
FIRMWARE VERSION DISPLAY MODE
Press TARE/ PT to enter , display shows the firmware version ,
Press TARE/ PT key again, the display shows maintenance number
for 1
seconds
Press ON/ZERO key to back to the last screen, display shows
BACK TO THE LAST SCREEN
Press TARE/ PT key to exit self-test mode, the scale will re-power on automatically.