8
01011020
ZSME100000080
EXCELL PRECISION CO., LTD.
Chapter 3 Operating Instructions
3-1 Internal
Value Display Mode
Press
Z
key, when the display show “
” ,then press
CE
key immediately. The display will show internal value. Press
0
to exit the
internal value mode and return to the weighing mode.
3-2 Setting up Backlight Mode (option)
Press
Z
key, the display will show “
” ,then press
4
key right
away. It is “auto-backlight mode”.
Press
Z
key, the display will show “
”, then press
5
key right
away. It is “backlight-off mode”.
Auto-backlight mode
When there is a weight on the pan which weight is over 10d or pressing any keys, the
backlight will be on. After back to zero for 10 seconds (the weight is under 10d),
backlight will be off
.
The scale will keep the auto-backlight mode after the next bootup,
If the auto-backlight mode is set before last power-off.
3-3 Selecting the Pricing Unit
n
Press
.
key two times, the display will show the current pricing unit.
z
3
kg
kg
3
.
o
Press
1
~
6
to select pricing units. The scale will be back to weighing & price
mode. The display will show the symbol indication “
◄
” for the request pricing unit.
1
⇒
kg
2
⇒
100g 3
⇒
HK catty
4
⇒
tl.T
5
⇒
lb
6
⇒
oz
If the price unit
“
lb
"
is seleteced, the displaying will show three symbols
“
3
"
.
If the price unit
“
oz
"
is selected, the displaying will
not
show any symbol
“
3
"
.