Excell ESW Скачать руководство пользователя страница 6

 

                                                                                            

               

 

 
EXCELL PRECISION CO., LTD.     

02005311  

ZSME3000000272 

 

Chapter 1 Introduction  

1-1 Features and Specifications 

Features: 

‹

  Sealed waterproof silica gel strip blocks water from infiltrating into the scale. 

‹

  Surrounded by waterproof grade sheeting to ensure the water free. 

‹

  1/3,000~1/6,000 display resolution available. 

‹

  Aluminum frames coated with anti-corrosion treatment for longer lifespan. 

‹

  Stainless steel made feet and platter for anti-rust. 

‹

  High speed of 24bits AD fast reacts and shortens the weighing operation duration. 

‹

  Selectable units: Kilogram (kg), gram (g), ounce (oz), and pound (lb) weighing units 

available. 

‹

  Built-in rechargeable battery can be easily replaced. 

‹

  Low power indication and auto power off. 

‹

  Well-designed protection point for transportation.  

‹

  Concave handle for easy carrying. 

 

Specifications: 
 

 
 
 
 
 
 

 

 

 

 

 

 

 
 
 
 
 

Model Capacity 

Division 

Resolution 

ESW-3 3kg 

0.5g 

1g 

1/6,000 
1/3,000 

ESW-6 6kg 

1g 
2g 

1/6,000 
1/3,000 

ESW-15 15kg 

2g 
5g 

1/7,500 
1/3,000 

ESW-30 30Kg 

5g 

10g 

1/6,000 
1/3,000 

Operating Temperature: Non-approval model: 

0°C ~ 40°C (32°F ~ 104°F)

 

                                          

Approval model: 

-10°C ~ 40°C (14°F ~ 104°F)

 

Dimensions:

 240 x 120 x 280 mm ( W x H x D)

 

Weight of the scale:

 Around 3.5kg

 

240mm 

280mm 

120mm 

Содержание ESW

Страница 1: ...rein is the property of Excell Precision Limited and is supplied without liability for errors or omissions No part may be reproduced or used except as authorized by contract or other written permissio...

Страница 2: ......

Страница 3: ...8 1 7 WEIGHT UNIT 8 CHAPTER 2 ADVANCED FUNCTIONS 9 2 1 ADVANCED FUNCTION SETTING TABLE 9 2 2 ADVANCED FUNCTION SETTING WORKFLOW 10 2 3 GENERAL FUNCTION SETTING 11 2 3 1 Automatic Backlight Function Se...

Страница 4: ...of any kind 3 If possible avoid connecting the scale to ac power outlet sockets which are adjacent to other appliances to minimise the possibility of interference affecting the performance of the sca...

Страница 5: ...de 3 Do not short the battery terminals to check whether there is current Please check whether the connection point is firm to guarantee good connection 4 The battery should be replaced by specialized...

Страница 6: ...hortens the weighing operation duration Selectable units Kilogram kg gram g ounce oz and pound lb weighing units available Built in rechargeable battery can be easily replaced Low power indication and...

Страница 7: ...gain 1 3 Panel and Keyboard Introduction Icon Introduction STABLE The weight is stable GROSS The scale is in the gross mode The display shows the goods and any container weight This Gross status indic...

Страница 8: ...ght units the icons or arrows will indicate the active units as appropriate The units available are dependent on the exact scale model After power off the scale will memorize the active units When the...

Страница 9: ...r the arrow pointing to the icon will be on When the or are indicated the scale is still operational but the count may contain errors To power off in this mode the scale will memorize the Pcs unit Whe...

Страница 10: ...0 002204623 lb lb oz 1 g 0 03527396 oz INTERNAL VALUE MODE must hook up Load Cell to test c Press TARE to enter and the display shows internal value d Please check whether the internal value has chang...

Страница 11: ...LAY LEVEL 1 FUNCTION DISPLAY LEVEL 2 FUNCTIONS Exit the ADVANCED FUNCTION setting mode Return to theADVANCED FUNCTION setting menu Automatic backlight function setting Automatic power off timer settin...

Страница 12: ...The LCD shows Overall workflow of the Advanced Function setting mode General Function setting mode External Weight Calibration Reserved Exit the Advanced Function setting mode Refer to the following...

Страница 13: ...c Power off Timer Settings Hi Lo OK Settings Restore the Default Settings Noise Filter Settings Hold Function Settings Auto Unit Weight Averaging Setting Refer to the following sections for detailed o...

Страница 14: ...t function When the weight is over 10d the display backlight will be on After the weight is stable for 10 seconds or when the scale returns to zero the display backlight switches off DISPLAY ACTIONS N...

Страница 15: ...Timer Setting Select in the General Function setting mode to change the automatic power off timer setting LCD displays the last status Automatic power off function When the weight on weigh pan is les...

Страница 16: ...esired low limit value Press TARE key Key in the parameter setting for alarm Press TARE key LCD displays the last status LCD displays the last status Alarm setting a b c The definition of a b c positi...

Страница 17: ...4 Sampling setting for the counting function For OIML NTEP or Sri Lanka approved models setting is disabled ACTIONS DISPLAY NOTE Return Cancel the restoration Restore to the default setting Press TARE...

Страница 18: ...etting Use ON ZERO or UNITS keys to key in the parameters Default setting 5 Parameter 0 9 the larger the number the faster the filter response Fast response can lead to weight instability Digital swit...

Страница 19: ...weight is continually changing To exit this mode press any key Stable hold 1 mode When the weight is stable the LCD shows the current weight value To exit this mode press any key Stable hold 2 mode W...

Страница 20: ...or UNITS keys to key in the parameters Default setting 0 0 Auto unit weight averaging 1 Non auto unit weight averaging ON ZERO key Upward key from 0 to 9 UNITS key Downward key from 9 to 0 TARE key M...

Страница 21: ...e maximum capacity of 1st unit and the unit The digit on the right side keeps flashing The scale is calculating the internal value of the zero point After stabilization the LCD shows the calibration w...

Страница 22: ...CO LTD 02005311 ZSME3000000272 Appendix 1 7 Segment Display Characters Digit 7 segments letter Alphabet 7 segments letter Alphabet 7 segments letter 0 A N 1 B O 2 C P 3 D Q 4 E R 5 F S 6 G T 7 H U 8 I...

Отзывы: