62
04011010
EXCELL PRECISION CO., LTD
ZSME400000002
Setting value
Item Function
Parameter
Description
Default
FNC-06
Front panel indication
“
◄
”
setting (top)
0
FNC-07
Front panel indication
“
◄
”
setting (next to top)
1
FNC-08
Front panel indication
“
◄
”
setting (next to bottom)
2
FNC-09
Front panel indication
“
◄
”
setting (bottom)
Parameter
⇒
Description
0
⇒
Zero
1
⇒
MD
2
⇒
Gross
3
⇒
Net
4
⇒
Totalised weight (Accu. V)
5
⇒
Totalised transactions (Accu. C)
6
⇒
SP1
7
⇒
SP2
8
⇒
SP3
9
⇒
Hi
10
⇒
OK
11
⇒
Lo
12
⇒
Under
13
⇒
Over
14
⇒
Discharge
15
⇒
Running
16
⇒
Hold
3
0 5
d
1 10
d
2 20
d
3 40
d
4 60
d
5 80
d
6 100
d
7 150
d
8 200
d
FNC-10
Return to zero band
(d: refer to CSP-03)
9 250
d
0
0 Hold
1
Peak hold (positive 1)
2
Peak hold (negative)
3
Peak hold (absolute value)
FNC-11 Hold
4
Peak hold (positive 2)
0
0 No
limitation
1 20
times/s
2 10
times/s
3 5
times/s
FNC-12 Rate for display rewrite
4 1
time/s
0