EXCELL PRECISION CO., LTD.
26
02029010
ZSME300000363
3-6
ID Code Setting
(Use must be in coordination with
,
,
)
Use
key or
key to select F11 function
the display shows
RS232 DATA FORMAT
Stable transmission
(
)
, Continuous transmission
(
)
,
Press
key to transmit
(
)
1. e.g. Machine ID code is 10.
The gross weight (+0.876 kg) shows as below, after stable: (no tare or under pre-tare
mode)
1
0
S
T
,
G
S
,
+
0
0
0
.
8
7
6
k
g 0D 0A
ID HEAD1 , HEAD2 , DATA UNIT
C
LF
2. e.g. Machine ID code is 00. (Not using Machine ID function.)
The net weight (-1.568 lb) shows as below without weight stability: (under tare or pre-tare mode)
U
S
,
N
T
,
-
0
0
1
.
5
6
8
l
b 0D 0A
HEAD1
, HEAD2, DATA UNIT
C LF
Machine ID code setting:
Press
and
to set 01 ~ 99
Default setting: 00
(1)
“00”: RS-232 does not transmit Machine ID
(2)
“01~99”: RS-232 transmits Machine ID
Press
key
Press