background image

EXCELL PRECISION CO., LTD.

 

 

                                     

 

                                                     

   

   

         

                                               

10 

02029010 

ZSME300000363 

     

Alarm Mode Settings

Sets High Limit (weight alarm limit). Low Limit is disabled (you can be freely set 
any Low Limit value without any effect). The beeper setting is 32. 

                                                    3    2 

 

 

                                             

     

 

A   

 

 

When weight alarm limit is reached, RelayCard (HIGHT) is activated with one 
weight totalizing. When weight returns to zero, the weight alarm is deactivated (the 
LCD indication is off, and RelayCard returns to normal). Totalized weight values 
range from [000.000] to [999999]. 

     

Clearing Alarm Totalized Weight Values: 

             

 Press 

  key followed by 

  key, then all totalized weight values are cleared. 

             

 When switching among weighing, counting, and alarm totalizing modes, or when 

changing among the weighing units, totalized weight values are automatically 
cleared. 

             

 After turning off the electronic scale, totalized weight values are automatically 

cleared. 

 

 

 

LCD indication:

 

 

   

     

     

 

 

                                               





     

 





 

                                              10d    Low Limit                    High Limit 

 

      To exit preset mode, please press 

  key. 

 

 

  2. Recall Check-weighing Values 

              Press 

  key then press 

  key 

 Recall 

“Low limit value” 

              Then press 

  key again 

 Recall 

“High limit value” 

              Then press 

  key again   

 Recall 

“Beeper value” 

              Then press 

  key again       

 Back to the beginning 

 

  3. Clearing Check-weighing Values 

  Press 

key then press 

key, and then press 

key 

 Recall 

“Low limit value” 

  Then press 

  key again 

 Clear 

“High limit value” and “Beeper value” 

  Press 

  key then press 

  key 6 times continuously 

 Clear all values. 

 

Содержание AWH4 Series

Страница 1: ...LTD 2017 All rights reserved worldwide The information contained herein is the property of EXCELL PRECISION CO LTD and is supplied without liability for errors or omissions No part may be reproduced o...

Страница 2: ...2 2 WEIGHING MODE 8 2 2 1 Units Selection 8 2 2 2 Check Weighing Mode 8 2 2 3 Totalizing 11 2 2 4 Zero Function 11 2 2 5 Tare Function 12 2 3 COUNTING FUNCTION 13 2 3 1 Sampling 13 2 3 2 Check Weighin...

Страница 3: ...welcome Preparing to Use the Scale 1 Locate the scale on a firm level surface free from vibrations for accurate weight readings Adjust the four leveling feet to centre the leveling bubble on the scale...

Страница 4: ...3 Do not short the battery terminals to check whether there is current Please check whether the connection point is firm to guarantee good connection 4 The battery should be replaced by specialized pe...

Страница 5: ...calibration High resolution models 10000 30000 Do linearity calibration first specification calibration weight calibration at last 3 One group of RS232 option 4 4 HOLD functions contain animal scale...

Страница 6: ...OK value The value between HI and LO limit value Low limit value Zero indication Net weight indication Low battery power indication 1 Stable indication 2 Pre tare mode indication 3 Totalizing mode in...

Страница 7: ...is key to tare deduct the container weight Press this key to preset tare value Press this key to recall the totalization value preset value and pre tare value Press this key to clear the totalization...

Страница 8: ...perating again Please recharge at once when the symbol shows in order to keep the weight accuracy 1 5 Error Messages Weight exceeds 9d of maximum capacity d division Zero point positive deviation afte...

Страница 9: ...tael or viss as the screen indicated 2 The selected unit will be memorized when you turn the indicator off And the memorized unit will appear after you turn on the indicator next time 2 2 2 Check Weig...

Страница 10: ...hat LCD is on and the beeper beep 0 When stable the beeper beeps and LCD is on 1 When stable the beeper beeps whether stable or not LCD is on 2 Whether stable or not the beeper beeps and LCD is on 3 A...

Страница 11: ...alues are cleared When switching among weighing counting and alarm totalizing modes or when changing among the weighing units totalized weight values are automatically cleared After turning off the el...

Страница 12: ...be used up to a maximum of 9999 times before it must be reset The totalizing display is limited to 6 digits maximum When totalizing RS 232 will also output Refer to F5 setting 2 Clear Totalized Weigh...

Страница 13: ...ue pre set tare value can equal the full capacity of the indicator 2 When the weight of the container is known Press key and the display shows Use and keys to input weight value of the container After...

Страница 14: ...e Too Small Sample is less than 20 divisions Unit Weight Too Small Unit weight is less than 0 2 division 0 1 d for Brazil regulation When sampling the above two symbols indications are on Under such c...

Страница 15: ...nters into the configuration setting mode and is showed on the display Press key Press key Press key Press key Press key Press key Press key Press key Press key Press key Press key Press key Press key...

Страница 16: ...K LO values Press key kg key Increase the flash value by one from 0 to 9 key Confirm key kg A B A 0 After stable the beeper beeps and the indications are on 1 After stable the beeper beeps whether sta...

Страница 17: ...le mode Press key to transmit in complete mode Stable transmission in totalizing mode The format is as same as Reserved Reserved Press key to transmit The format is as same as and Continuous transmiss...

Страница 18: ...ansmission Press key to transmit 1 gram as weight unit 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 g HEAD HEAD DATA UNIT CR LF 2 kg or lb as weight unit 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 kg l...

Страница 19: ...a format for RS 232 continuous transmission are as below 1 The gross weight 0 876 kg shows as below after stable no tare or pre tare mode S T G S 0 8 7 6 k g 0D 0A HEAD1 HEAD2 DATA UNIT C LF 2 The net...

Страница 20: ...1 0000 Press or key 0005 5 0000 Press twice to print TOTAL Press key to transmit complete mode G GROSS T TARE PT PRE TARE N NET Press or key Press or key Press twice to print TOTAL TICKET NO 0001 G 1...

Страница 21: ...0000 The scale is stable 0002 1 0000 The scale is stable 0003 1 0000 The scale is stable 0004 1 0000 The scale is stable 0005 1 0000 The scale is stable 0005 5 0000 Press twice to print TOTAL RS232 ou...

Страница 22: ...m Brazil customer Print out format F R W T 3 N LF LF G G G G G LF T T T T T LF PT PT PT PT PT LF N N N N N LF pcs pcs pcs pcs pcs pcs LF n n n n n n t t t t t t pcs pcs pcs pcs pcs pcs LF p 1 1 LF For...

Страница 23: ...3 Exit Function Setting Mode Use or key to select F6 function the display shows 3 4 Internal Value Display Mode Use or key to select F7 function the display shows Press key Counting down to zero and e...

Страница 24: ...can set RS232 to print the HOLD value on display after making appropriate settings press to print By sequentially pressing key the screen will sequentially display selected hold mode w After selecting...

Страница 25: ...xit this mode press any key except the key Stable hold 2 mode When the weight is stable the LCD holds the currently displayed weight value value will not change with external changing factors The scal...

Страница 26: ...tted Deviation Range Use and keys to set Enter a range between 1 and 100 The default range is 10 Number of Samples to Take an Average Use and keys to set The available choices are 1 2 4 8 16 32 and 64...

Страница 27: ...g shows as below after stable no tare or under pre tare mode 1 0 S T G S 0 0 0 8 7 6 k g 0D 0A ID HEAD1 HEAD2 DATA UNIT C LF 2 e g Machine ID code is 00 Not using Machine ID function The net weight 1...

Страница 28: ...print current weight if weight variation is within 1d 10d or to print accumulated weight if weight variation is over 10d d division Press key to print the current weight at once no totalization Press...

Страница 29: ...ELL PRECISION CO LTD 28 02029010 ZSME300000363 Appendix 1 7 Segment Display Characters Number Display Letter Display Letter Display 0 A N 1 B O 2 C P 3 D Q 4 E R 5 F S 6 G T 7 H U 8 I V 9 J W K X L Y...

Отзывы: