1. In order to prevent the scale from dust and static electricity, please fix the dustproof 

cover on the scale with double-sided adhesive. 

2. The scale should not be drenched by rain or water. (If it gets wet carelessly, please 

wipe it dry with a cloth. If its operation is abnormal, please send it to our distributor for 

service. ) 

3. Please keep the scale in a cool and dry place. Do not store at high temperatures or 

damp places. 

4. Please keep the scale clean and free from insect infestation. 

5. To avoid impact and it is to be used under designated pressure (the weight put on the 

platter can not exceed the maximum capacity of the scale). 

6. If the scale is not going to be used for some time, please clean it and store it in a plastic 

bag in dry condition. A desiccant sachet may be included to prevent moisture build up. 

The scale should be recharged every 3 months to prevent failure of the internal 

rechargeable battery. 

7. The commodity should be placed in the center of platter for accurate weighing. The 

dimension of the weighted commodity should not exceed the dimension of platter. 

8. Please release the protection screw “

4

” before weighing. 

9. Please operate or charge the scale in an open area. Do not squeeze the power cord to 

avoid wire on fire. 

10.  Operating temperature: -10

 ~ + 40

 

11.  Any suggestion for product is welcomed. 

Preparation Before Using 

1.  Put the scale on a firm level surface free for accurate weight readings. Adjust the four 

leveling feet to get the leveling bubble at the centre of circle. 

2. Scale must be used under a stable temperature and stable air flow. Avoid direct 

sunlight onto the scale or near the exhaust port of ventilating system.   

3. Scale must be used under individual socket to avoid the interference of other electric 

appliances. 

4.  Remove any weight that might be on the platter before the scale is switched on.   

5. Please note that when      or        symbol appears on the screen, the scale needs

 

to 

be charged. 

6.   Introduction of Storage Battery 

Thank you for purchasing Price Computing Scale. In order to 

operate smoothly, to last the durability, and to reduce the chance of 

breakdown for this product, please read this Manual carefully. 

Содержание 20key

Страница 1: ...erein is the property of EXCELL PRECISION CO LTD and is supplied without liability for errors or omissions No part may be reproduced or used except as authorized by contract or other written permissio...

Страница 2: ...CHAPTER 2 KEYBOARD FUNCTION 6 3 1 INTERNAL VALUE DISPLAY MODE 7 3 2 SETTING UP BACKLIGHT MODE OPTION 7 3 3 SETTINGS OF PRICING UNIT 7 3 4 35 PRESET OPERATING INSTRUCTION 8 3 5 EXTERNAL WEIGHT CALIBRAT...

Страница 3: ...d be placed in the center of platter for accurate weighing The dimension of the weighted commodity should not exceed the dimension of platter 8 Please release the protection screw 4 before weighing 9...

Страница 4: ...3 Do not short the battery terminals to check whether there is current Please check whether the connection point is firm to guarantee good connection 4 The battery should be replaced by specialized pe...

Страница 5: ...9 division of maximum capacity Zero value above 10 full scale Zero value below 10 full scale The internal value is over 350 000 The internal value is below 80 000 If the negative weight is over 20 di...

Страница 6: ...rge Voltage 1 AC 110 V 10 15 2 AC 220 V 10 15 Power Consumption 30 mA system no backlight About 140 hours 40 mA system front display backlight About 100 hours 50 mA system front display backlight rear...

Страница 7: ...n TOTAL PRICE as same as the calculator s multiply At that moment please press to store it in accumulation 1 1 Input unit price in the UNIT PRICE then press to memorize the sum M After the number on T...

Страница 8: ...ode or backlight off mode Auto backlight mode When there is a weight on the pan which weight is over 10d or pressing any keys the backlight will be on After back to zero for 10 desonds the weight is u...

Страница 9: ...0 00 0 00 1 Both the scale is empty and there is weight on are ok 2 0 000 1 23 0 00 Press 01 35 you can call input unit price 3 5 External Weight Calibration Steps 1 Make sure the scale backs to zero...

Страница 10: ...3 keys to choose 0 1 2 3 in order 0 9600 bits second 1 4800 bits second 2 2400 bits second 3 1200 bits second Press T key to enter the next setting mode Press M key to save setting values The scale wi...

Страница 11: ...232 1 Continuous transmission only RS 232 2 Stable transmission only RS 232 3 RS 232 off 4 Continious transmission weight transmission only 5 Stable transmission weight transmission only 6 Continuous...

Страница 12: ...CH input PAY 1000 proper amounts press CHANGE 300 MC key again to print PAY and CHANGE If necessary When F2 setting is 4 or 5 the RS232 format is as below 4 Continious transmission weight transmissio...

Страница 13: ...ight unit is g lb or oz 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 twg HEAD HEAD DATA UNIT CR LF 4 Weight unit is Catty 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Catty HEAD HEAD DA...

Страница 14: ...0A HEAD HEAD DATA UNIT C LF 2 The net weight 1 568lb shows as below after unstable under tare or pre tare mode U S N T 0 0 1 5 6 8 l b 0D 0A HEAD HEAD DATA UNIT C LF 3 The net weight 15 TW Catty and 6...

Страница 15: ...EXCELL PRECISION CO LTD 01008044 ZSME100000113 Appendix 7 Segment Display Characters Number Display Letter Display Letter Display 0 A N 1 B O 2 C P 3 D Q 4 E R 5 F S 6 G T 7 H U 8 I V 9 J W K X L Y M...

Отзывы: