![Excelitas Technologies 019-00187R Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/excelitas-technologies/019-00187r/019-00187r_user-manual_2449429017.webp)
13
035-00540R-r4
6
Connecting the UV LED Head
6.1
Interfacing with the PLC
PLC Input Signal Requirements
Digital
Analog
Input
Voltage: 0 – 24V
Current: 1 – 30mA
Voltage: 0 – 5V
Current: 500uA
Output
Voltage: 0 – 5V
Current: 2.5mA (max.)
PLC Connector Pin-Out
Figure 7 PLC Connector (looking at UV Head)
PIN
Name
Description
1
Intensity Input
Input voltage is converted to required current to achieve desired intensity;
intensity will vary linearly between 20% and 100% for voltages between 1V
and 5V respectively.
A minimum voltage of 0.4V is required for proper light source operation. If
the user inputs a voltage
below
the minimum required, the light source will
not turn on.
2
Enable High
0.0V to +0.6V = Turns LEDs off (Open input will default to OFF).
+2.4V to +24.0V = ON.
3
Enable Low
0.0V to +0.6V = Turns LEDs on.
+2.4V to +24.0V = Turns LEDs off (Open input will default to OFF).
4
Thermal Fault
0.0V to +0.4V (ground) = Fault
+2.4V to +5.0V (open) = No Fault
5
IsoDGND
Ground Reference for digital IOs
6
IsoVCC
+5.0V Output.
7
Reserved
Do not connect
8
Door Lock *
0.0V to +0.6V = UV Emission Allowed.
+2.4V to +24V = UV Emission Stopped.
9
IsoGND
Ground Reference for analog IOs.
10
LED ON
0.0V to +0.4V (ground) = LED off
+2.4V to +5.0V (open) = LED on.
11
Reserved
Do not connect
12
UV LED Fault
0.0V to +0.4V (ground) = Fault
+2.4V to +5.0V (open) = No Fault
13
Reserved
Do not connect