Excel XL8800 Series Скачать руководство пользователя страница 2

Right hand fitting only, use reverse for left hand fitting.

3  8 

4

  1  1  3 

EN1154:1996 / A1:2002 / AC:2006

EN1634-1:2008 FD30/FD60 Timber Doors

Fig 1 Application Only

30/60

C

XL8800 Series 

Door Closer Installation

b

2

 

2

3

1

4

5

6

7

8

9

Parallel

Arm Bracket

Power Adjustment Valve - 5 

Door Closer Body

2 - Latching Speed 

Valve

1 - Closing Speed 

Valve

3 - Delayed

 Action 

Valve

4- Back Check 

Valve

Hinge knuckle

is 

not

 visible

Key

1.

Armset Pivot Screw

2.

Adjustable Forearm

3.

Armset

4.

Fixing Screw

5.

Parallel Arm Bracket (Figure 66) 

6.

Door Closer Body

7.

Dust Cap

8.

Assembling Screw

9.

Armset Shoe

Preload

Parallel Arm Installation

(Push Side) - Fig 66

15

˚

65

˚

Latching Speed

Closing Speed

Delayed Action & Back Check

Step by Step Installation Guide

Use the appropriate template for your installation and place

the template on the door and frame. Pilot drill all fixing holes

as per the template.

1.

Position the door closer with the power adjustment valve

facing towards the hinge side of the door. Secure the

door closer using the screws provided into the pre-drilled

pilot positioning holes.

2.

Attach the armset to the pivot on the door closer body parallel

to the door/frame and secure using the washer screw.

3.

Tension the door closer arm and adjust the arm length

accordingly. Secure the armset shoe to the figure 66 bracket and tighten

the arm set fixing screw (4).

4.

Add the dust cap to the unused pivot.

5.

Make necessary adjustments to closing, latching,

back check, delayed action and door closer power valves

as required (refer to valve adjustment instructions).

NB after the first month of operation the adjusment valves

may require minor adjustment.

SPRING POWER ADJUSTING VALVE

Controls opening and closing force

Factory setting size 3

Adjust according to table to change 

closer size when needed

D o o r C lo ser Size 

(2-4)

A pplicable do o r 

weight (kg)

A pplicable max. 

do o r width (mm)

N o . o f turns 

F ro m facto ry set 

po sitio n

EN2

30-45

900

-5

EN3

45-65

1000

0

EN4

65-80

1200

5

SPRING POWER-ADJUSTMENT CHART FOR DOOR SELECTIONS     

(Up to 1200mm Door Height)

CAUTION

Adjusting valves more than 2 full turns 

anti-clockwise from factory settings will 

result in oil leakage damaging the door closer. 

Failure to comply with this will void the warranty.

Acceleration

Deceleration

Valve Adujustment Instruction Guide

Closing Speed:

 Adjust valve by quarter turns 

anti-clockwise to increase speed or clockwise to 

reduce speed. 

Latching Speed: 

Adjust valve by quarter turns 

anti-clockwise to increase speed or clockwise to 

reduce speed.

Delayed Action:

 Adjust valve by quarter turns 

anti-clockwise to increase speed or clockwise to 

reduce speed.

Back Check: 

Adjust valve by quarter turns 

anti-clockwise to increase speed or clockwise to 

reduce speed.

Power Adjustment: 

Adjust valve by quarter turns 

anti-clockwise to reduce power or clockwise to 

increase power.

Отзывы: