Right hand fitting only, use reverse for left hand fitting.
3 8
4
1 1 3
EN1154:1996 / A1:2002 / AC:2006
EN1634-1:2008 FD30/FD60 Timber Doors
Fig 1 Application Only
30/60
C
XL8800 Series
Door Closer Installation
b
2
2
3
1
4
5
6
7
8
9
Parallel
Arm Bracket
Power Adjustment Valve - 5
Door Closer Body
2 - Latching Speed
Valve
1 - Closing Speed
Valve
3 - Delayed
Action
Valve
4- Back Check
Valve
Hinge knuckle
is
not
visible
Key
1.
Armset Pivot Screw
2.
Adjustable Forearm
3.
Armset
4.
Fixing Screw
5.
Parallel Arm Bracket (Figure 66)
6.
Door Closer Body
7.
Dust Cap
8.
Assembling Screw
9.
Armset Shoe
Preload
Parallel Arm Installation
(Push Side) - Fig 66
15
˚
65
˚
Latching Speed
Closing Speed
Delayed Action & Back Check
Step by Step Installation Guide
Use the appropriate template for your installation and place
the template on the door and frame. Pilot drill all fixing holes
as per the template.
1.
Position the door closer with the power adjustment valve
facing towards the hinge side of the door. Secure the
door closer using the screws provided into the pre-drilled
pilot positioning holes.
2.
Attach the armset to the pivot on the door closer body parallel
to the door/frame and secure using the washer screw.
3.
Tension the door closer arm and adjust the arm length
accordingly. Secure the armset shoe to the figure 66 bracket and tighten
the arm set fixing screw (4).
4.
Add the dust cap to the unused pivot.
5.
Make necessary adjustments to closing, latching,
back check, delayed action and door closer power valves
as required (refer to valve adjustment instructions).
NB after the first month of operation the adjusment valves
may require minor adjustment.
SPRING POWER ADJUSTING VALVE
Controls opening and closing force
Factory setting size 3
Adjust according to table to change
closer size when needed
D o o r C lo ser Size
(2-4)
A pplicable do o r
weight (kg)
A pplicable max.
do o r width (mm)
N o . o f turns
F ro m facto ry set
po sitio n
EN2
30-45
900
-5
EN3
45-65
1000
0
EN4
65-80
1200
5
SPRING POWER-ADJUSTMENT CHART FOR DOOR SELECTIONS
(Up to 1200mm Door Height)
CAUTION
Adjusting valves more than 2 full turns
anti-clockwise from factory settings will
result in oil leakage damaging the door closer.
Failure to comply with this will void the warranty.
Acceleration
Deceleration
Valve Adujustment Instruction Guide
Closing Speed:
Adjust valve by quarter turns
anti-clockwise to increase speed or clockwise to
reduce speed.
Latching Speed:
Adjust valve by quarter turns
anti-clockwise to increase speed or clockwise to
reduce speed.
Delayed Action:
Adjust valve by quarter turns
anti-clockwise to increase speed or clockwise to
reduce speed.
Back Check:
Adjust valve by quarter turns
anti-clockwise to increase speed or clockwise to
reduce speed.
Power Adjustment:
Adjust valve by quarter turns
anti-clockwise to reduce power or clockwise to
increase power.