![Excel XL8800 Series Скачать руководство пользователя страница 1](http://html1.mh-extra.com/html/excel/xl8800-series/xl8800-series_quick-start-manual_2449295001.webp)
Power Adjustment Valve - 5
Frame Fix Installation - View from below
Push Side - Fig 61
Hinge Knuckle
Adjustment Valves
Door Closer Body
Preload
Armset
Nut
Threaded
Arm (bolt)
Armset Shoe
Washer Screw
Armset Pivot Screw
Dust Cap
Standard Door Installation - View from above
Pull Side - Fig 1
Washer Screw
Dust Cap
Armset Pivot Screw
Hinge Knuckle
Adjustment Valves
Door Closer Body
Preload
Armset
Nut
Threaded
Arm (bolt)
Armset Shoe
Left hand fitting only, use reverse for right hand fitting.
XL8800 Series
Door Closer Installation
3 8
4
1 1 3
EN1154:1996 / A1:2002 / AC:2006
EN1634-1:2008 FD30/FD60 Timber Doors
Fig 1 Application Only
30/60
C
b
2
Door Closer Body
Door Closer Body
2 - Latching Speed
Valve
1- Closin
g Speed
Valve
3- Delayed
Action
Valve
4 - Back Check
Valve
2- Latching Speed
Valve
1 - Closing
Speed
Valve
3- Delayed
Action
Valve
4 - Back Check
Valve
Hinge knuckle
is visible
Hinge knuckle
is
not
visible
Standard Door Installation
(Pull Side) - Fig 1
Frame Fix Installation
(Push Side) - Fig 61
Armset Shoe
Armset Shoe
Power Adjustment Valve - 5
Step by Step Installation Guide
Use the appropriate template for your installation and place
the template on the door and frame. Pilot drill all fixing holes
as per the template.
1.
Position the door closer with the power adjustment valve
facing away from the hinge side of the door. Secure the
door closer using the screws provided into the pre-drilled
pilot positioning holes.
2.
Attach the armset to the pivot on the door closer body and
secure using the washer screw.
3.
Tension the door closer arm and adjust the arm length
accordingly. Secure the arm set shoe to the door or frame
depending on installation, then tighten the arm set screw.
4.
Apply the dust cap to the unused pivot.
5.
Make necessary adjustments to closing, latching,
back check, delayed action and door closer power valves
as required (refer to valve adjustment instructions).
NB after the first month of operation the adjusment valves
may require minor adjustment.
15
˚
65
˚
Latching Speed
Closing Speed
Delayed Action & Back Check
SPRING POWER ADJUSTING VALVE
Controls opening and closing force
Factory setting size 3
Adjust according to table to change closer size when needed
D o o r C lo ser Size
(2-4)
A pplicable do o r
weight (kg)
A pplicable max.
do o r width (mm)
N o . o f turns
F ro m facto ry set
po sitio n
EN2
30-45
900
-5
EN3
45-65
1000
0
EN4
65-80
1200
5
SPRING POWER-ADJUSTMENT CHART FOR DOOR SELECTIONS
(Up to 1200mm Door Height)
CAUTION
Adjusting valves more than 2 full turns
anti-clockwise from factory settings will
result in oil leakage damaging the door closer.
Failure to comply with this will void the warranty.
Acceleration
Deceleration
Valve Adujustment Instruction Guide
Closing Speed:
Adjust valve by quarter turns
anti-clockwise to increase speed or clockwise to
reduce speed.
Latching Speed:
Adjust valve by quarter turns
anti-clockwise to increase speed or clockwise to
reduce speed.
Delayed Action:
Adjust valve by quarter turns
anti-clockwise to increase speed or clockwise to
reduce speed.
Back Check:
Adjust valve by quarter turns
anti-clockwise to increase speed or clockwise to
reduce speed.
Power Adjustment:
Adjust valve by quarter turns
anti-clockwise to reduce power or clockwise to
increase power.