Excel XL8800 Series Скачать руководство пользователя страница 1

Power Adjustment Valve - 5

Frame Fix Installation - View from below

Push Side - Fig 61

Hinge Knuckle

Adjustment Valves

Door Closer Body

Preload

Armset

Nut

Threaded

Arm (bolt)

Armset Shoe

Washer Screw

Armset Pivot Screw

Dust Cap

Standard Door Installation - View from above

Pull Side - Fig 1

Washer Screw

Dust Cap

Armset Pivot Screw

Hinge Knuckle

Adjustment Valves

Door Closer Body

Preload

Armset

Nut

Threaded

Arm (bolt)

Armset Shoe

Left hand fitting only, use reverse for right hand fitting.

XL8800 Series 

Door Closer Installation

3  8 

4

  1  1  3 

EN1154:1996 / A1:2002 / AC:2006

EN1634-1:2008 FD30/FD60 Timber Doors

Fig 1 Application Only

30/60

C

b

2

Door Closer Body

Door Closer Body

2 - Latching Speed 

Valve

1- Closin

g Speed 

Valve

3- Delayed

 Action 

Valve

4 - Back Check 

Valve

2- Latching Speed 

Valve

1 - Closing

 Speed 

Valve

3- Delayed

 Action 

Valve

4 - Back Check 

Valve

Hinge knuckle

is visible

Hinge knuckle

is 

not

 visible

Standard Door Installation

(Pull Side) - Fig 1

Frame Fix Installation

(Push Side) - Fig 61

Armset Shoe

Armset Shoe

Power Adjustment Valve - 5

Step by Step Installation Guide

Use the appropriate template for your installation and place

the template on the door and frame. Pilot drill all fixing holes

as per the template.

1.

Position the door closer with the power adjustment valve

facing away from the hinge side of the door. Secure the

door closer using the screws provided into the pre-drilled

pilot positioning holes.

2.

Attach the armset to the pivot on the door closer body and

secure using the washer screw.

3.

Tension the door closer arm and adjust the arm length

accordingly. Secure the arm set shoe to the door or frame

depending on installation, then tighten the arm set screw.

4.

Apply the dust cap to the unused pivot.

5.

Make necessary adjustments to closing, latching,

back check, delayed action and door closer power valves

as required (refer to valve adjustment instructions).

NB after the first month of operation the adjusment valves

may require minor adjustment.

15

˚

65

˚

Latching Speed

Closing Speed

Delayed Action & Back Check

SPRING POWER ADJUSTING VALVE

Controls opening and closing force

Factory setting size 3

Adjust according to table to change closer size when needed

D o o r C lo ser Size 

(2-4)

A pplicable do o r 

weight (kg)

A pplicable max. 

do o r width (mm)

N o . o f turns 

F ro m facto ry set 

po sitio n

EN2

30-45

900

-5

EN3

45-65

1000

0

EN4

65-80

1200

5

SPRING POWER-ADJUSTMENT CHART FOR DOOR SELECTIONS     

(Up to 1200mm Door Height)

CAUTION

Adjusting valves more than 2 full turns 

anti-clockwise from factory settings will 

result in oil leakage damaging the door closer. 

Failure to comply with this will void the warranty.

Acceleration

Deceleration

Valve Adujustment Instruction Guide

Closing Speed:

 Adjust valve by quarter turns 

anti-clockwise to increase speed or clockwise to 

reduce speed. 

Latching Speed: 

Adjust valve by quarter turns 

anti-clockwise to increase speed or clockwise to 

reduce speed.

Delayed Action:

 Adjust valve by quarter turns 

anti-clockwise to increase speed or clockwise to 

reduce speed.

Back Check: 

Adjust valve by quarter turns 

anti-clockwise to increase speed or clockwise to 

reduce speed.

Power Adjustment: 

Adjust valve by quarter turns 

anti-clockwise to reduce power or clockwise to 

increase power.

Отзывы: