Installer Programmable Features (cont’d)
“Tachless Hi”
sensitivity mode looks for a voltage increase of 0�3v after cranking� It
uses a fixed crank time determined by installer feature #5.
“Tachless Lo”
sensitivity mode looks for a voltage increase of 0�5v after cranking� It
uses a fixed crank time determined by installer feature #5.
“Tach wire”
monitors the “Violet/white wire” (see the installation manual for the
Tach Learn Procedure)� It will crank the engine until a tach signal is detected (3
seconds max)�
“Data Tach”
mode operates just like the “Tach wire” setting except it takes its
reading from the D2D data port instead of using the Violet/white wire� Before using,
make sure this function is supported by the Databus Interface module�
“Crank Only”
AKA “blind start” is similar to the “Tachless” settings however, it only
makes one start attempt and does not monitor engine running conditions� This is
useful for many “push-to-start” vehicles�
Feature #4 Gasoline Or Diesel Engine
Gasoline
(press “lock” button to program)
- DEFAULT
Diesel 15 Sec� Delay
(press “unlock” button to program)
Diesel 20 Sec� Delay
(press “trunk” button to program)
Diesel 30 Sec� Delay
(press “start” button to program)
This feature changes the system’s timing of the ignition and starter output sequence
for gas or diesel engines� gasoline: the starter output will occur 3 seconds after the
ignitions turn on� when in “Tachless” mode, the engine running status is determined
10 seconds after cranking� Diesel: the starter output will occur 15, 20, or 30 seconds
after the ignitions turn on (allows for glow plug warming)� when in “Tachless” mode,
the engine running status will be determined 40 seconds after cranking�
Feature #5 Satellite Relay Port Green wire Function
Start
(press “lock” button to program)
- DEFAULT
Pulse After Engine Start
(press “unlock” button to program)
Status Output
(press “trunk” button to program)
Domelight
(press “start” button to program)
Start
setting operates as a secondary START output� This will have the same pulse
timing as the large Violet wire on the main harness�
Pulse After Start
setting will give a 0�8 second pulse immediately after the engine
starts and is running�
Status Output
setting will behave like the ignition output except it turns on 1�5
seconds earlier than the primary ignition output��
Domelight
provides domelight supervision output� It will turn on when the system is
unlocked and after turning the ignition “off”�
Feature #6 Satellite Relay Port Blue wire Function
Status
(press “lock” button to program)
- DEFAULT
Ignition
(press “unlock” button to program)
Status
- operates like the PInK ignition output except it turns on 1�5 seconds earlier
than the PInK ignition #1 output� This is best for activating bypass kits�
Ignition
- operates with the same timing as the PInK ignition #1 output�