Excalibur RS-330-EDPB Скачать руководство пользователя страница 13

13

Installer Programmable Features (cont’d)

“Tachless Hi”

 sensitivity mode looks for a voltage increase of 0�3v after cranking� It 

uses a fixed crank time determined by installer feature #5.

“Tachless Lo”

 sensitivity mode looks for a voltage increase of 0�5v after cranking� It 

uses a fixed crank time determined by installer feature #5.

“Tach wire”

 monitors the “Violet/white wire” (see the installation manual for the 

Tach Learn Procedure)� It will crank the engine until a tach signal is detected (3 

seconds max)�

“Data Tach”

 mode operates just like the “Tach wire” setting except it takes its 

reading from the D2D data port instead of using the Violet/white wire� Before using, 

make sure this function is supported by the Databus Interface module� 

“Crank Only”

 AKA “blind start” is similar to the “Tachless” settings however, it only 

makes one start attempt and does not monitor engine running conditions� This is 

useful for many “push-to-start” vehicles�

Feature #4   Gasoline Or Diesel Engine

Gasoline

   

 

(press “lock” button to program)

 - DEFAULT

Diesel 15 Sec� Delay

  (press “unlock” button to program)

Diesel 20 Sec� Delay

  (press “trunk” button to program)

Diesel 30 Sec� Delay

  (press “start” button to program)

This feature changes the system’s timing of the ignition and starter output sequence 

for gas or diesel engines� gasoline: the starter output will occur 3 seconds after the 

ignitions turn on� when in “Tachless” mode, the engine running status is determined 

10 seconds after cranking� Diesel: the starter output will occur 15, 20, or 30 seconds 

after the ignitions turn on (allows for glow plug warming)� when in “Tachless” mode, 

the engine running status will be determined 40 seconds after cranking� 

Feature #5   Satellite Relay Port Green wire Function

Start 

  

 

 

 

(press “lock” button to program) 

 - DEFAULT

Pulse After Engine Start

  (press “unlock” button to program)

Status Output

   

 

(press “trunk” button to program)

Domelight

   

 

 

(press “start” button to program)

Start

 setting operates as a secondary START output� This will have the same pulse 

timing as the large Violet wire on the main harness�  

Pulse After Start

 setting will give a 0�8 second pulse immediately after the engine 

starts and is running�

Status Output

 setting will behave like the ignition output except it turns on 1�5 

seconds earlier than the primary ignition output��

Domelight

 provides domelight supervision output� It will turn on when the system is 

unlocked and after turning the ignition “off”�

Feature #6   Satellite Relay Port Blue wire Function

Status

 

(press “lock” button to program) 

- DEFAULT

Ignition

  (press “unlock” button to program)

Status 

- operates like the PInK ignition output except it turns on 1�5 seconds earlier 

than the PInK ignition #1 output� This is best for activating bypass kits�

Ignition

 - operates with the same timing as the PInK ignition #1 output�

Содержание RS-330-EDPB

Страница 1: ...RS 340 EDP Deluxe Keyless Entry Remote Start Operation Guide June 29 2011 Temporary cover Color cover is in a separate file...

Страница 2: ...Features 11 Installer Programmable Features 12 Programmable Features Matrix 15 This device complies with FCC Rules part 15 Operation is subject to the following two conditions 1 This device may not ca...

Страница 3: ...bleshooting failed remote start attempts as well as in customizing the programmable features The specific opera tions of the lights are described on page 8 The Valet Switch is used to access transmitt...

Страница 4: ...emble the transmitter case LOCK Press and release the LOCK button The doors will lock the parking lights will flash and the horn will honk once UNLOCK Press and release the UNLOCK button The doors wil...

Страница 5: ...is active If the engine stalls the system will make up to 3 more attempts Each time you park your vehicle set the climate controls to give you the desired interior temperature when you use the remote...

Страница 6: ...the vehicle s data network Consult with your installing dealer to find out if any of these functions are available for your vehicle If so confirm each operation with the transmitter and write each fu...

Страница 7: ...l honk 3 times activating low voltage start mode To activate low temp starting enter low voltage start mode as described above but before the horn honks press the valet switch 1 time 15 degrees or 2 t...

Страница 8: ...ess the programming functions With the system in a locked state simply turn the ignition key to the RUN ON position and press and release the valet switch once Using The Valet Switch Other Remote Star...

Страница 9: ...the system in your car has the key to decipher this code and it is not replicable Automatic Transmitter VerificationTM There is also the potential threat of someone who has temporary access to your ve...

Страница 10: ...turn on the Unauthorized Transmitter Alert feature Follow the same steps as the Standard Programming but on any transmitter con troller being programmed instead of pressing the lock button press the...

Страница 11: ...eady press lock button to program DEFAULT Flashing press unlock button to program This Feature configures the operation of the vehicle s parking lights during the remote start operation The default se...

Страница 12: ...button presses press trunk button to program 4 button presses press start button to program This feature allows you to choose the number of button presses AND pulses required on the White Blue activa...

Страница 13: ...Gasoline the starter output will occur 3 seconds after the ignitions turn on When in Tachless mode the engine running status is determined 10 seconds after cranking Diesel the starter output will occ...

Страница 14: ...ds on the correct connection of the neutral safety wire to the vehicle s parking brake Please refer to the installation manual for details Feature 8 Low Temp Crank Extender 0ms Off press lock button t...

Страница 15: ...TE Wire Function Ignition Accessory Start 3 Engine Detection Tachless Hi Tachless Lo Tach Wire Datatach Crank Only press Lock Unlock 4 Gas or Diesel Engine Gas Diesel 15 sec Diesel 20 sec Diesel 30 se...

Страница 16: ...Back Cover Color cover is in a separate file...