6.
The Water Softener inlet/outlet plumbing will be installed
downstream of outdoor spigots. Install an inlet shutoff valve
and plumbing to the Water Softener bypass valve located at
the right rear as you face the Water Softener. There are a
variety of Water Softener installation fittings available. They
are listed under Water Softener installation fitting
assemblies. When assembling the Water Softener
installation fitting package (inlet and outlet) connect the
fitting to the plumbing system first and attach the Water
Softener nut, split ring and o-ring. Heat from soldering or
solvent cements may damage the Water Softener nut, split
ring or o-ring. Solder joints should be cool and solvent
cements should be set before installing the Water Softener
nut, split ring and o-ring. Avoid getting solder flux, primer
and solvent cement on any part of the Water Softener o
rings, split rings, bypass valve or control valve. If the
building electrical system is grounded to the plumbing
system, install a copper grounding strap from the inlet to the
outlet plumbing.
7. WATER SOFTENER DRAIN LINE
First, be sure that the Water Softener drain line can handle the
flow rate of the Water Softener. Solder joints near the drain line
must be done prior to connecting the Water Softener drain line
flow control fitting. Leave at least 6 inched between the Water
Softener drain line flow control fittings and solder joints. Failure to
do this could cause interior damage to the Water Softener flow
control. Install a ½ inch inside diameter flexible plastic tube to the
Water Softener drain line assembly or discard the tubing nut and
the 3/4 inch NPT fitting for rigid pipe. If the Water Softener
backwash flowrate is greater than 7 gallons per minute, use a ¾
inch Water Softener drain line. Where the Water Softener drain
line is elevated but empties into a water drain below the level of
the Water Softener control valve, form a 7 inch loop at the
discharge end of pipe so that the bottom of the loop is level with
the drain connection of the Water Softener control valve. This will
provide an adequate anti-siphon trap. Where the drain empties
into an overhead sewer pipe, a sink-type trap must be used. Run