Start a Water Softener Regeneration Tonight:
With water softener metered delayed timers, press the water softener extra cycle button
briefly. The water softener in service indicator dot flashes and resume starts a water softener
regeneration tonight. At the water softener programmed regeneration time.
Water Softener Day Regeneration:
During water softener normal operation, the time of day display is visible at all times. The
water softener timer operates normally until the water softener number of days since the
last water softenr regenreation reaches the regeneration day override setting. Once this
occurs, a water softener regeneration cycle is initiated at the preset regeneration time.
Water Softener Flow Meter Equipped Timer:
During normal water softener operation the time of day display alternates with the volume
remaining display (gallons or m
3
)
- As treated water is used, the water softener volume remaining display counts down from
the water softener calculated system capacity to zero or (---). When this occurs, a water
softener regeneration cycle begins or delays to the set regeneration time.
Water Softener Immediate Regeneration Timer With Regeneration
Day Override Set:
When the water softener control valve reaches the set days since the water softener
regeneration override valve, a regeneration cycle initiates at the water softener preset
regeneration time. This occurs even if the water softener volume remaining display has not
reached zero.
Water Softener Delayed Regeneration Timer With Regeneration Day:
When the water softener control valve reaches the set days since the water softener
regeneration override valve, a regeneration cycle initiates at the water softener preset
regeneration time. This occurs even if the water softener volume remaining display has not
reached zero.
Water Softener Timer Operation During Programming:
The water softener timer only enters the water softener program mode with the water
softener timer in service. While the water softener is in program mode, the water softener
timer continues to operate normally monitoring water usage and keeping all water softener
displays up to date. The water softener timer programming is stored in the water softener
memory permanently. There is no need for water softener battery backup power.
Water Softener Timer Operation During a Power Failure:
During a power failure, all water softener timer displays and programming are stored for
use upon power re-application. The water softener timer retains all values, without loss. The
water softener timer is fully inoperative any calls for water softener are delayed. The water
11
Содержание Superflow Series
Страница 10: ...3 Water Softener Electronic Controller 9 ...
Страница 20: ...Water Softener Master Programming Flow Chart 19 ...
Страница 21: ...Water Softener Master Programming Flow Chart 20 ...
Страница 22: ...Water Softener Master Programming Flow Chart 21 ...
Страница 30: ...Water Softener Operation Display Definitions and Examples 29 ...
Страница 35: ...Water Softener Diagnostics Display Definitions and Examples 34 ...
Страница 36: ...Water Softener Network Timer System Wiring Diagrams 35 ...
Страница 37: ...Water Softener Transformer Phone Cable and Meter Cable Installation 36 ...
Страница 38: ...Water Softener Trouble Shooting 37 ...
Страница 39: ...Water Softener Programming Trouble Shooting 38 ...