FILTER INSTALLATION AND USER GUIDE 

 

BARRIE 

 ONTARIO 

 CANADA     705.733.8900     WWW.EXCALIBURWATER.COM

 

 

Outlet Meter Port 

Drawing No.

 

Order No.

 

Description

 

Quantity

 

1

 

CLK V3151

 

WS1 Nut 1” QC

 

1

 

2

 

CLK V300301

 

WS1 Meter Plug ASY

 

1

 

CLK V3105

 

O-ring 215

 

1

 

 

* CLK V3003 includes CLK V311801 and CLK V3105 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

 

Содержание FILTERMAX ZENTEC

Страница 1: ...BARRIE ONTARIO CANADA 705 733 8900 WWW EXCALIBURWATER COM FILTERMAX ZENTEC FILTER INSTALLATION AND USER GUIDE...

Страница 2: ...3 Manual Regeneration 9 2 4 Setting Time of Day 10 2 5 User Displays 10 2 6 Installer Display Settings 11 2 7 Installer Display Settings Weekly 12 2 8 System Setup 14 3 Model Variable Components and S...

Страница 3: ...ly with minor plumbing changes on previous plumbing The piping must be clamped properly and the weight of the plumbing must not be on the filter Do not use any kind of lubricant including silicone A s...

Страница 4: ...3 FILTER INSTALLATION AND USER GUIDE BARRIE ONTARIO CANADA 705 733 8900 WWW EXCALIBURWATER COM Installation Drawing...

Страница 5: ...must be installed at the inlet of the filter 5 The bypass valve must be installed on the control valve 6 The outside tap water if possible may be bypassed from the filter 7 The primer solder or solde...

Страница 6: ...g and solder joints The gap less than this can damage the flow control If the drain line is elevated and then emptied into the drain below the level the of control valve then 7 loop should make at the...

Страница 7: ...e pointing the direction of flow indicated by the engraved arrows on the control valve Water flows through the control valve in normal operation as a water filter BYPASS OPERATION The inlet and outlet...

Страница 8: ...the control valve and the plumbing system while not allowing water to exit from the control valve to the plumbing Unfiltered water is supplied to the house in this position SHUT OFF MODE The inlet ha...

Страница 9: ...manual regeneration The drive motor will start to reach backwash cycle and countdown time begins C1 Turn the inlet bypass valve handle halfway into the direction of diagnose operation Once the steady...

Страница 10: ...reset time The arrow will point the word REGEN which indicates the regeneration is expected tonight Press and buttons again to cancel the scheduled regeneration for tonight Immediate Regeneration Pres...

Страница 11: ...ion is supposed to occur at a scheduled time of day Step 1 Push SET button and hold for 3 seconds Step 2 When hour flashes press or until the correct hour is displayed Then press SET to proceed to nex...

Страница 12: ...y 6 d6 Friday day 7 d7 Saturday Step 1 Press and hold SET and buttons for 3 seconds Step 2 When hour flashes press or until the correct hour is displayed Then press SET to proceed to next step Step 3...

Страница 13: ...Step 3I7 Set the regeneration time minutes using or buttons Press SET to proceed to step 4I7 Step 4I7 Set the current day of the week by using or buttons Refer to the table on previous page Press SET...

Страница 14: ...ess SET to proceed to step 9I7 Step 9I7 Thursday d5 regeneration Use or button to point the REGEN arrow then regeneration will occur every Thursday Press SET to proceed to step 10I7 Step 10I7 Friday d...

Страница 15: ...remium models Step 1SS Press and hold SET and buttons simultaneously for 3 seconds and release Again press and hold SET and buttons simultaneously for 3 seconds and release Step 2SS Press or buttons t...

Страница 16: ...ows through the upper basket and flows down to the bottom distributor In this operation water is filtered downward through Media C1 Cycle In Backwash Cycle water flows in upflow direction the water en...

Страница 17: ...ypass the supply water to the demand C4 Cycle In Rinse Cycle water flows rapidly in downflow direction through the Media to the drain This cycle pack the media bed and washes the media particles in do...

Страница 18: ...IVE BRACKET SPRING CLIP 1 4 CLK V3818TC WS1TC PC BOARD 4 DIGIT 1 5 CLK V3110 WS1 DRIVE REDUCING GEAR 12 X 36 3 6 CLK V3109 WS1 DRIVE GEAR COVER 1 Not Shown CLK V3186 WS1 AC ADAPTER 120V 12V 1 CLK V318...

Страница 19: ...er stack Drawing No Order No Description Quantity 1 CLK V3005 WS1 Spacer Stack Assembly 1 2 CLK V3004 Drive Cap ASY 1 3 CLK V3178 WS1 Drive Back Plate 1 4 CLK V3011 WS1 Piston Downflow ASY 1 5 CLK V31...

Страница 20: ...Injector Assembly Drawing No Order No Description Quantity 1 CLK V3176 INJECTOR CAP 1 2 CLK V3152 O RING 135 1 3 CLK V30101Z WS1 INJECTOR ASY ZPLUG 1 Not Shown CLK V3170 O RING 011 1 Not Shown CLK V3...

Страница 21: ...TALLATION AND USER GUIDE BARRIE ONTARIO CANADA 705 733 8900 WWW EXCALIBURWATER COM Brine Tank Port Drawing No Order No Description Quantity 1 CLK V319501 WS1 Refill Port Plug Asy 1 2 CLK H4615 Elbow L...

Страница 22: ...lbow Locking Clip 1 2 CLK PKP10TS8BU Polytube insert 5 8 Option 3 CLK V3192 WS1 Nut Drain Elbow Option 4 CLK V315801 WS1 Drain Elbow Male 1 CLK V315802 WS1 Drain Elbow Male No 5 CLK V3163 O ring 019 1...

Страница 23: ...E ONTARIO CANADA 705 733 8900 WWW EXCALIBURWATER COM Outlet Meter Port Drawing No Order No Description Quantity 1 CLK V3151 WS1 Nut 1 QC 1 2 CLK V300301 WS1 Meter Plug ASY 1 3 CLK V3105 O ring 215 1 C...

Страница 24: ...CLK V3105 O Ring 215 2 4 CLK V3145 WS1 Bypass 1 Rotor 2 5 CLK V3146 WS1 Bypass Cap 2 6 CLK V3147 WS1 Bypass Handle 2 7 CLK V3148 WS1 Bypass Rotor Seal 2 8 CLK V3152 O ring 135 2 9 CLK V3155 O ring 112...

Страница 25: ...SSSWEATASSEMBLYLF 2 Do not install in California CLK V300703LF WS1 Fitting Brass Sweat Assembly LF Drawing No Order No Description Quantity 1 CLK V3151 WS1 NUT 1 QUICK CONNECT 2 2 CLK V3150 WS1 SPLIT...

Страница 26: ...Assembly LF Drawing No Order No Description Quantity 1 CLK V3151 WS1 NUT 1 QUICK CONNECT 2 2 CLK V3150 WS1 SPLIT RING 2 3 CLK V3105 O RING 215 2 4 CLK V3628LF WS1 FTG 3 4 BRASS SHARKBITE LF 2 CLK V300...

Страница 27: ...Reset regeneration time 3 Time of day flashes on and off a Power outage a Reset time of day If PC Board has battery back up present the battery may be depleted See Front Cover and Drive Assembly drawi...

Страница 28: ...c Main drive gear too tight c Loosen main drive gear Press NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC Board for 5 seconds a...

Страница 29: ...COM Possible Error Codes Code Description E1 Control unable to sense motor movement E2 Control Valve motor ran too short E3 Control Valve motor ran too long and unable to find next cycle E4 Control V...

Страница 30: ...on will occur tonight at preset time The delayed regeneration can be cancelled by pressing UP and DOWN buttons again The bypass valve handles must be turned towards the center as shown above The bypas...

Страница 31: ...n regeneration 4SS Regen Time Arrow DP switch trigger for scheduled regeneration Press SET and UP arrow button simultaneously for 3 seconds Adjust hour of the time of regeneration by using UP or DOWN...

Страница 32: ...ion must be given to your local Excalibur Water Systems Dealer General Provisions The above warranties are effective provided the Zentec Filter is operated at water pressures not exceeding 125psi and...