Exalt Installation and Management Guide
EX-r Series GigE Digital Microwave Radios
11
201872-003
2015-10-23
Radio A/ B Configuration
Use the Exalt GUI to configure the radio terminals for Radio A and Radio B orientation. Since many
other parameters also need to be set, and the Exalt GUI is needed for these configurations, this is the
best way to completely configure the radio terminals.
Radios arrive from manufacture in default configuration, orientated as Radio B and configured as
shown in Table 1.
Note:
It is not always necessary to synchronize collocated radios. If antennas are substantially
separated or blocked from one another and/or frequency separation tuning is used, the
opportunity for near-end interference can be eliminated.
Note:
When GPS synchronization is required or desired, one GPS kit is required for each EX-
r Series GigE radio link in the connected or collocated network.
Table 1 Factory default settings
Parameter
Setting
Transmit Power
+4dBm
Link Distance
<10 miles
Bandwidth
8 MHz (10 MHz for some regulatory domains)
Mode
Mode 1
TDD Frame Size
2ms
Link Security Key
000000000000
Administration Password
password
User Password
password
IP Address
10.0.0.1
IP Mask
255.0.0.0
IP Gateway
0.0.0.0
Ethernet Interface
Alarm Enabled, Auto-negotiate
T1/E1 Enabling
All Disabled
Note:
In many cases, the system design will not be identical to the factory default
configuration, and in some cases, these differences prohibit the installation of the radio. If at
all possible, obtain a computer and configure the radio terminals using the browser-based
GUI. See
Exalt Graphical User Interface (GUI)
for details.