Ex-Cell Excell A05982 Скачать руководство пользователя страница 5

5

9.

Do not connect tool 

to pressure which

potentially exceeds 200 PSI (13.7 BAR).

10. All air line components (hoses,
connectors, filters, regulators, etc.) 

must

be rated for a maximum working pressure
of at least 150 PSI (10.3 BAR) or 150% of
the maximum system pressure, which ever
is greater.

11. Connect tool to air supply hose

with a

coupling that automatically removes all
pressure from the tool when the coupling is
disconnected. Fig. 7.

12. Disconnect tool from air supply hose

before doing tool maintenance, clearing a
jammed fastener, leaving work area, moving
tool to another location, or handing the tool
to another person. Fig. 7.

13. Never use a tool

that is leaking air, has

missing or damaged parts, or requires
repair. Make sure all screws and caps are
securely tightened. Fig. 8.

14. Never use tool if safety, trigger or
springs 

are inoperable, missing or

damaged. Do not alter or remove safety,
trigger, or springs. Make daily inspections
for free movement of trigger and safety
mechanism. Fig. 8.

15. Do not use tool without safety
warning label.

If label is missing, damaged

or unreadable, contact the Customer Care
Department at 1-800-888-2468 for a
replacement. Fig. 9.

16. Only use parts and accessories

approved by DeVilbiss Air Power Company.

17. Connect tool to air supply before

loading fasteners, to prevent a fastener
from being fired during connection. The tool
driving mechanism may cycle when tool is
connected to the air supply. Fig. 10.

18. Always assume the tool contains
fasteners.

No horseplay. Respect the tool

as a working implement. Fig. 11.

19. Operator and bystanders should wear
hard hats

to safeguard against possible

injuries. Fig. 12.

20. Keep bystanders and children away
from work area 

when operating this power

tool. 

Fig. 8

Fig. 9

Fig. 11

Fig. 12

Fig. 7

Fig. 10

Содержание Excell A05982

Страница 1: ...Power Company Part No A05982 07 22 04 Owners Manual for models EBN125 EBN200 Brad Nailers Record All Information and attach sales receipt here for future reference Purchase Date __________________________ Serial ________________________________ Do Not return this product to the retailer Questions 1 800 888 2468 Learn more about your tool get answers to frequently asked questions and register on li...

Страница 2: ...mbre d ordre TABLE OF CONTENTS SAFETY GUIDELINES AND INSTRUCTIONS 3 GENERAL SAFETY RULES 4 6 FUNCTIONAL DESCRIPTION 7 PREPARING THE TOOL 8 OPERATING INSTRUCTIONS 9 10 MAINTENANCE 10 SERVICE 11 TROUBLESHOOTING 11 WARRANTY SERVICE INFORMATION 12 ESPAÑOL 13 24 FRANÇAISE 25 36 213 Industrial Drive Jackson TN 38301 9615 Telephone 1 800 888 2468 FAX 1 800 888 9036 ...

Страница 3: ...lways be followed to reduce the risk of personal injury Improper operation maintenance or modification of tools or equipment could result in serious injury and property damage There are certain applications for which tools and equipment are designed DeVilbiss Air Power Company strongly recommends that this product NOT be modified and or used for any application other than for which it was designed...

Страница 4: ...chanism is bumped while the trigger is depressed 4 Choice of triggering method is important Check manual for triggering options See Using the Tool section of this manual 5 Never point tool at yourself or others in work area Serious injury or death may occur if the tool is activated Fig 3 6 Never use oxygen or other bottled gases Explosion will occur Never use combustible gases or any other reactiv...

Страница 5: ...Never use tool if safety trigger or springs are inoperable missing or damaged Do not alter or remove safety trigger or springs Make daily inspections for free movement of trigger and safety mechanism Fig 8 15 Do not use tool without safety warning label If label is missing damaged or unreadable contact the Customer Care Department at 1 800 888 2468 for a replacement Fig 9 16 Only use parts and acc...

Страница 6: ...en With Contact Actuation tools an unwanted fastener will be fired if the safety mechanism is allowed to recontact work surface before trigger is released 26 Do not drive fasteners on top of other fasteners or with the tool at too steep an angle the fasteners can ricochet causing personal injury Fig 15 27 Do not drive fasteners close to the edge of the workpiece The workpiece is likely to split al...

Страница 7: ...picture mirror frames and crafts Features include jam release mechanism tool free adjustable exhaust fastener reload indicator safety positioned on rear of nose and removable rubber nose cushion 1 Brad Nailer 3 Air Tool Oil Bottle 2 Brad Nails 4 Owner s Manual POWER SOURCE This tool is designed to operate on clean dry compressed air at regulated pressures between 70 and 110 PSI Pounds per Square I...

Страница 8: ...h the bottom of the magazine channel A Fig 20 4 Push magazine cover closed Fig 21 5 Observe the low fastener indicator A Fig 22 and reload as needed 6 Adjust directional exhaust deflector A Fig 23 so that the exhaust air or debris will be directed away from the operator Grasp the deflector and rotate it to the desired position for the current application PREPARING THE TOOL NOTE This tool is shippe...

Страница 9: ...fastener is driven This single sequential actuation method provides the most accurate fastener placement Disconnect tool from air supply before performing maintenance clearing a jammed fastener leaving work area moving tool to another location or handing the tool to another person Clean and inspect tool daily Carefully check for proper operation of trigger and safety mechanism Do Not use the tool ...

Страница 10: ...rews tight Loose screws can cause personal injury or damage tool If tool is used without an in line oiler place 5 or 6 drops of Air Tool Oil into the air inlet of the tool at the beginning of each workday CLEARING A JAMMED FASTENER Disconnect tool from air supply 1 Open magazine and remove remaining fasteners Fig 26 and Fig 27 NOTE Remove fasteners from tool before opening the fastener guide plate...

Страница 11: ...pply before performing any Service Procedure SYMPTOM PROBLEMS SOLUTIONS 1 Air leak near top of Loose screws Tighten screws tool or in trigger area Worn or damaged Install Overhaul Kit o rings or seals 2 Tool does nothing or Inadequate air supply Verify adequate air supply operates sluggishly Inadequate lubrication Put 5 or 6 drops of oil into air inlet Worn or damaged Install Overhaul Kit o rings ...

Страница 12: ...does not receive satisfactory results from the Authorized Warranty Service Center the purchaser should contact DeVilbiss Air Power Company THIS WARRANTY DOES NOT COVER Merchandise sold as reconditioned used as rental equipment or floor or display models Merchandise that has become damaged or inoperative because of ordinary wear misuse cold heat rain excessive humidity freeze damage use of improper...

Отзывы: