background image

Chapter 6

Check Card Detection on the Embedded Web

Page

6. Check Card Detection on the Embedded Web Page

The eWON Flexy Extension Card requires no software configuration. It is automatically 
detected by the Base Unit when it boots. 

6.1. Connecting to the Embedded Web Server

Configure the network parameters of your configuration PC to encompass the IP range of 
the eWON LAN. 
Connect the PC to one of the LAN port of the eWON Flexy.
Open your Internet browser and access the eWON Flexy internal Web page by entering the 
LAN IP address in the URL field (the default address is 

http://10.0.0.53

). 

The default 

login is adm

password is adm

- Important -

For security reasons, changing the default password 

adm

 is absolutely required.

To change the 

adm 

password, from the menu bar, click on 

Configuration

Users Setup

 and double 

click on the 

adm

 entry to edit its parameters.  Enter the new password twice and click 

Save

.

6.2. Detected Cards Displayed in the System Page

The 

System

 page allows to check the status of the system including detected Extension 

Cards. To access the system status summary, click on 

Diagnostic (1)

 

> Status (2) > System 

Info (3) > System (4). 

The screen capture below gives an example of an FLB 3202 extension 

card that has been detected in slot 3 (5).

Page 15 / 17

eWON Flexy                   3G GSM Extension Card  FLB 3202 | IG 019

Содержание FLB 3202

Страница 1: ...support ewon biz eWON Flexy 3G GSM Extension Card FLB 3202 This installation guide explains how to install the eWON Flexy 3G GSM Extension Card FLB 3202 Installation Guide IG 019 Rev 1 4...

Страница 2: ...sion Cards 8 3 3 Front Panel LEDs 8 3 4 Specifications of the 3G GSM Extension Card 9 3 5 eWON Flexy Extension Cards Environmental Conditions 10 3 6 Plugging the Extension Card into the Base Unit 10 3...

Страница 3: ...nations of Extension Cards and Base Units The present Installation Guide is focusing on an extension card which as such needs to be inserted in one of the Base Units in order to work The Base Units ha...

Страница 4: ...to avoid ESD damage the product must be handled with the necessary precaution including Grounded ESD protective work surface Personnel grounding 2 3 Applicable Directives Standards and Compliance The...

Страница 5: ...mful interference and This device must accept any interference received including interference that may cause undesired operation 2 3 4 Certifications The Extension Card described in the present Insta...

Страница 6: ...3 Hardware Description 3 Hardware Description 4 Mechanical Layout and Interfaces SMA F Female antenna connector SIM Card drawer Backplane connector Page 6 17 eWON Flexy 3G GSM Extension Card FLB 3202...

Страница 7: ...bed below PN Part Number identifies the type of the card Description see 4 1 2 Part Number Structure for Extension Cards SN Serial Number Structure of the Serial Number 1111 2233 0001 44 1111 MTID pro...

Страница 8: ...only X In any slot 3202_00 3G GSM Extension Card The suffix _00 is used for software options S The suffix might have an optional character It might also be blank or include S character Indicates comp...

Страница 9: ...Class 5 band GPRS EDGE Class 33 Antenna Connector Type SMA F Female Antenna not included in the delivery Charact Value s Range Depending on frequency band s provided by the network operator the custo...

Страница 10: ...rature 40 to 70 C Relative humidity 10 to 95 non condensing Operating altitude Up to maximum 2000m Storage altitude Up to maximum 3000m 4 5 Plugging the Extension Card into the Base Unit 4 5 1 Base Un...

Страница 11: ...X 2 last slots only B 4 5 2 SIM Card Insertion A SIM card obtained from a wireless phone provider is necessary to communicate through the 3G GSM Extension Card It should be inserted before inserting t...

Страница 12: ...PCB acts as mistake proof security mating stop in housing Insert the Extension Card carefully and slide it down until the hooks are clicking Make sure the card is completely inserted DO NOT insist if...

Страница 13: ...al power converter of the eWON Flexy Base units has been dimensioned to cover a broad range of different combinations of Extension Cards Users should make sure the total power demand of the Extension...

Страница 14: ...in which the extension cards have been inserted and their type are detected during this process If the boot process completes normally you should observe the following LED status Base Unit USR flashin...

Страница 15: ...the default address is http 10 0 0 53 The default login is adm password is adm Important For security reasons changing the default password adm is absolutely required To change the adm password from...

Страница 16: ...isplayed in the Info Page Extended information about the modem including manufacturer type and modem firmware version is available in the Info page The path to the Info page is Diagnostic 1 Status 2 S...

Страница 17: ...contain nor for their eventual consequences No liability or warranty explicit or implicit is made concerning the quality the accuracy and the correctness of the information contained in this document...

Отзывы: