Chapter 6
IP parameters configuration
Any other pattern will start with 200ms ON (opening of the pattern) followed by OFF and a
certain number of times 1 sec ON that allows to identify the nature of the detected
problem. Please call the technical support if you are confronted with an error pattern on the
“USER” LED.
-
WARNING
-
You absolutely have to wait until the full auto test procedure is completed without interrupting
it. If the auto test is interrupted, the flash memory of the eWON will contain random data likely
to make it unstable. In such a case you have to redo the full reset procedure from scratch and
wait until it is totally completed.
When performing a full reset, the eWON does NOT restart in normal mode by itself and remains
running in diagnose mode. Power the eWON OFF and ON again to restart in normal mode. As
described before, the eWON returns to its default COM parameters and IP addresses after this level 2
reset is performed.