support.ewon.biz
eWON 4005CD
This installation guide describes the hardware of theeWON 4005CD and explains how to get started withit.
Installation Guide
IG 002 / Rev. 1.9
Страница 1: ...support ewon biz eWON 4005CD This installation guide describes the hardware of the eWON 4005CD and explains how to get started with it Installation Guide IG 002 Rev 1 9...
Страница 2: ...2 3 3 5 Certifications 12 3 4 Equipment information versions 13 3 5 Mechanical Outline 14 3 6 Mounting environmental conditions 15 3 7 Preparing the installation 15 3 8 Specification for external Powe...
Страница 3: ...er Supply 27 Ethernet 27 Direct connection 29 Connection over Hub Switch Router 30 RJ 45 Connector 30 Inputs Outputs 31 Serial Port 32 MPI Port 33 PSTN ISDN Phone line connector 34 Antenna 35 Antenna...
Страница 4: ...ll the benefits of an universally recognized standard network It also allows you to use popular software tools like Internet Explorer FTP client SNMP Manager Mail Recipient and so to reduce significan...
Страница 5: ...penVPN technology 1 3 3 Remote Access Server functions Remote Access Server RAS and TCP IP Server PAP CHAP Authentication Login password Remote network access User access control Security NAT IP filte...
Страница 6: ...d vessel level monitoring Process and machinery activity logs Commissioning support Remote programming Interface for Application Service Providers ASP Datalogging 1 5 Part Numbers and internal options...
Страница 7: ...odem EW46203 eWON4005CD PSTN 56 PSTN 56 modem EW46204 eWON4005CD GPRS EDGE GPRS EDGE modem EW46207 eWON4005CD HSUPA HSUPA Tri band modem EW4620A eWON4005CD UMTS HSUPA HSUPAPenta band modem EW4620B eWO...
Страница 8: ...ype 2 Reference Guides Software Exhaustive reference guides to use all advanced functions of the eWON General Reference Guide RG 001 Programming Guide RG 002 Web reference guide RG 003 3 Application U...
Страница 9: ...Chapter 3 Housing markings 3 Housing markings 3 1 Housing interfaces Page 9 39 eWON 4005CD IG 002...
Страница 10: ...Chapter 3 Housing markings For HSUPA modem with part number EW2620A only the SIM card drawer is located on eWON top side See Embedded HSUPA modem Page 10 39 eWON 4005CD IG 002...
Страница 11: ...rial Number SN is an important traceability tool both for the user and for the manufacturer Therefore next to the product label each eWON has its serial number stored in the flash memory This SN is al...
Страница 12: ...less modem 3 3 3 Applicable Safety Standards The eWON4005CD range including optional modems is in conformity with the following safety standards IEC EN 60950 1 UL 60950 1 CSA C22 2 No 60950 1 07 3 3 4...
Страница 13: ...with any other transmitter or antenna To comply with regulations limiting both maximum RF output power and human exposure to RF radiation the maximum antenna gain including cable loss are given in th...
Страница 14: ...lace insert the upper slider into the upper part of the rail with the eWON tiled around 20 Then push and rotate the eWON downward to put the unit right The eWON4005CD is now safely fastened For HSUPA...
Страница 15: ...s only if the following environmental conditions are respected Environment Conditions Ambient temperature range 20 C to 70 C for eWON with GPRS EDGE HSUPA modem 0 C to 50 C for eWON with PSTN or ISDN...
Страница 16: ...lter Common mode filter Power absorbed 10 Watts Input Protection Protected against polarity inversion Properly ground the unit with the earth screw at the top of the unit This is mandatory to ensure t...
Страница 17: ...Chapter 4 Front panel control LED s 4 Front panel control LED s Front panel LED s description Page 17 39 eWON 4005CD IG 002...
Страница 18: ...in out RJ45 connector See RJ45 connector Please refer to the appendix Direct connection and Connection over Hub Switch Router for information on the different Ethernet connection modes straight and cr...
Страница 19: ...F Tightening torque for SMA antenna connector MAX 0 5N m manual tightening should be used as a reference See Antenna 5 5 Embedded GPRS EDGE Quad Band Modem optional Specification GPRS QB Bands Quad ba...
Страница 20: ...htening torque for SMA antenna connector MAX 0 5N m manual tightening should be used as a reference See Antenna 5 7 Embedded HSUPA Tri Band Modem optional Specification HSUPA Bands Quad band EGSM 850...
Страница 21: ...aud rate 921 kbps theoretical Compliant to standards R TTE CE FCC Certificate number Antenna connector Type SMA F Tightening torque for SMA antenna connector MAX 0 5N m manual tightening should be use...
Страница 22: ...nfigurable RS232 RS485 RS422 Isolation 1 kV by optocoupler Pin out connector See Serial Port The configuration of the physical serial mode is done by a set of 4 dip switches located on left side of th...
Страница 23: ...oth OFF When they are ON it connects the internal polarization typ 680 Ohms and termination typ 120 Ohms resistors This configuration applies only to RS485 RS422 lines conforming to good practices WAR...
Страница 24: ...e input level is above 10Vdc WARNING The logic level is undefined when the input is ranging between 5 and 10VDC 5 13 Digital output Specification Value Type of output Open drain MOSFET Max current ext...
Страница 25: ...ith a device of which you don t know the IP parameters Therefore there is a special tool called eBuddy you can download from the eWON Internet site http www ewon biz Start this application once you ha...
Страница 26: ...ry configuration IP address 10 1 0 53 Subnet mask 255 255 255 0 Gateway 0 0 0 0 WARNING By default the WAN interface is disabled Then first connection must be done by the LAN Modem Interface incoming...
Страница 27: ...until the procedure is completed The eWON restarts automatically and is ready to communicate This type of reset does not modify the communication parameters 6 1 2 Factory Reset This second level reset...
Страница 28: ...s completed without interrupting it If the auto test is interrupted the flash memory of the eWON will contain random data likely to make it unstable In such a case you have to redo the full reset proc...
Страница 29: ...Positive A 2 Ethernet By default only the LAN Ethernet interface of the eWON4005CDTM can be used to access the internal Web Site A 2 1 Ethernet LAN The Ethernet LAN is a four ports auto sense Etherne...
Страница 30: ...oth ends The type of cable straight or crossed depends on the equipment the eWON will be connected to The most current cases are the direct connection with a PC crossed and the connection through a hu...
Страница 31: ...use a crossover Ethernet cable to make a direct WAN connection When cabling over long distance you have to take care of the twisted pairs This means that along with the above cabling conventions the...
Страница 32: ...evice with a straight cable Again the wiring is as shown on the following picture and care should be taken to keep the RX and TX signals on twisted pairs A 5 RJ 45 Connector The RJ45 connector has got...
Страница 33: ...osition REF Description 1 DO GND Output digital signal 0V ground connected to the emitter of the transistor 2 DO Output digital signal connected to the drain of the MOSFET transistor 3 DO VDC Common o...
Страница 34: ...ial Port Mating female connector not included Type Female DB9 with 4 40 blocking screws Pin out Serial port according to mode PIN RS232 RS485 RS422 1 2 RXD RX 3 TXD A TX 4 5 GND GND GND 6 7 RTS RX 8 C...
Страница 35: ...ix A Pin outs connections A 8 MPI Port Mating male connector not included Type Male DB9 with 4 40 blocking screws MPI port pin out DB9 female PIN MPI 1 2 3 B 4 5 GND 6 7 8 A 9 Page 35 39 eWON 4005CD I...
Страница 36: ...ed Type RJ11 type 6P2C without shield PIN out PSTN PIN out ISDN PIN Description PIN Description 1 1 2 2 TX 3 TIP 3 RX 4 RING 4 RX 5 5 TX 6 6 The ISDN modem in the appliance shall be connected to the t...
Страница 37: ...850 900 1800 1900 MHz Impedance 50 Ohms Devices conformity has been assessed with the reference antenna Kinsun 6602G01081 eWON reference for the antenna is EW40923 or EW40922 for the antenna with a 2...
Страница 38: ...dem the conformity assessment has been performed with the reference antenna Taoglas TG 09 0113 eWON reference for the antenna is FAC90501_0000 or FAC90501_0100 for the antenna with a 2 meters length e...
Страница 39: ...implicit is made concerning the quality the accuracy and the correctness of the information contained in this document In no case the manufacturer s responsibility could be called for direct indirect...