Chapter 6
IP parameters configuration
6. IP parameters configuration
-
WARNING
-
Normally you cannot communicate with a device of which you don’t know the IP parameters.
Therefore, there is a special tool (called “eBuddy”) you can download from the eWON Internet
site
Start this application once you have connected your eWON to the network. The application
will scan the whole network and will identify all eWONs that are connected, including their IP
parameters (Address and subnet mask) and their serial number. The utility allows also to edit
the IP parameters. IP parameters always have to be defined in full agreement with network
policies applicable within your organization (ask your network administrator).
Default IP settings:
LAN Interface factory configuration
IP address
10.0.0.53
Subnet mask
255.255.255.0
WAN Interface factory configuration
IP address
10.1.0.53
Subnet mask
255.255.255.0
Gateway
0.0.0.0
-
WARNING
-
By default, the WAN interface is disabled. Then, first connection must be done by the LAN.
Modem Interface (incoming PPP) factory configuration
IP address
202.0.0.240
Subnet mask
255.255.255.0
- Note -
By default, the incoming PPP connection is allowed.
Page 23 / 36
eWON 2005CD | IG 001