Appendix A
Parameter overview
– setting ranges
099-00T406-EW501
13.07.2017
47
6.1.2
MMA welding
Name
Display
Setting range
Code
Standa
rd
Unit
Mi
n.
Max.
Main current AMP, depending on power source
-
A
-
-
-
Hot start current, percentage of AMP
150
%
1
-
150
Hot start current, absolute, depending on power source
-
A
-
-
-
Hot start time
0,1
s
0,0
-
5,0
Pulse current
142
1
-
200
Pulse frequency
1,2
Hz
0,2
-
50
Pulse balance
30
1
-
99
Dynamic power adjustment
16
A
16
-
20