![EWM Picomig 305 puls TKM Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/ewm/picomig-305-puls-tkm/picomig-305-puls-tkm_operating-instructions-manual_2448184048.webp)
Design and function
TIG welding
48
099-005639-EW501
04.06.2020
5.4.5 Expert menu (TIG)
The Expert menu has adjustable parameters stored that don’t require regular setting. The number of pa-
rameters shown may be limited, e.g. if a function is deactivated.
2s
2s
Figure 5-41
Display
Setting/selection
Gas pre-flow time
Ignition current (as percentage, dependent on main current)
Upslope time to main current
Downslope time
The downslope time can be set separately for latched and non-latched operation.
End-crater current
Setting range in percent: depending on main current
Setting range, absolute: Imin to Imax.