Functional characteristics
MIG/MAG welding
099-M183xA-EW501
15.7.2022
27
Display
Setting/selection
P
A
Main program
P
END
End program
Start current (as percentage, dependent on main current)
Start time (duration of start current)
Slope time of start program P
START
to main program P
A
Slope time of main program P
A
to end program P
END
End current (as a percentage, dependent on main current)
End current time (duration of end current)
5.2.7
Expert menu (MIG/MAG)
The Expert menu has adjustable parameters stored that don’t require regular setting. The number of pa-
rameters shown may be limited, e.g. if a function is deactivated.
2s
2s
Figure 5-14
Display
Setting/selection
Gas pre-flow time
Start current (as percentage, dependent on main current)
Start time (duration of start current)
Slope time of start program P
START
to main program P
A