Operating the machine control
Welding task administration (Menu)
099-00L105-EW501
07.06.2019
47
5.6.5.4 TIG welding
Figure 5-25
Menu item/parameter
Program
Comment
Gas pre-flow time
Gas nominal value
GFE option/variant (electronic gas volume con-
trol) required
Current
P
START
Ignition current
Duration
Duration (start program)
Slope time
Slope duration from P
START
to P
A
Current
P
A
Welding current, absolute
Duration
Pulse time (superPuls)
Slope time
Slope duration from P
A
to P
B
Current
P
B
Welding current
Duration
Pulse pause time (superPuls)
Slope time
Slope duration from P
B
to P
A
Slope time
Slope duration from P
A
to P
END
Current
P
END
Welding current
Duration
Gas post-flow time