Design and function
Transport and installation
099-005637-EW501
27.04.2021
19
5.1.2 Transport elements
Depending on the version, a transport handle and / or a transport belt are factory fitted to the machine. If
required, the respective transport element can be converted or retrofitted
> see 9 chapter
.
Figure 5-1
The machine can be carried either centrally by the transport handle (1) or with the transport belt (2).
5.1.3 Welding torch cooling system
Insufficient frost protection in the welding torch coolant.
Depending on the ambient conditions, different liquids are used to cool the welding
torch > see 5.1.3.1 chapter. Coolant with frost protection (KF 37E or KF 23E) must be checked at
regular intervals for sufficient frost protection to prevent damage to the machine or the acces-
sory components.
• The coolant must be checked with the frost protection tester TYP 1 > see 9 chapter for suffi-
cient frost protection.
• Replace coolant with insufficient frost protection if necessary.
Material damage due to unsuitable coolants!
Unsuitable coolant, coolants mixed with other types / liquids or use in an unsuitable tempera-
ture range will result in material damage and loss of the manufacturer's warranty!
• Operation without coolant is not permitted! Dry running will destroy the cooling components
such as the coolant pump, welding torch and hose packages.
• Only use the coolants described in these instructions for the specified ambient conditions
(temperature range) > see 5.1.3.1 chapter.
• Do not mix coolants of different types (including those described in these instructions).
• When changing the coolant, all liquid must be replaced and the cooling system flushed.
Dispose of the coolant in accordance with local regulations and the material safety data sheets.
5.1.3.1 Permitted torch coolant
Coolant
Temperature range
blueCool -10
-10 °C to +40 °C (14 °F to +104 °F)
KF 23E (Standard)
-10 °C to +40 °C (14 °F to +104 °F)
KF 37E
-20 °C to +30 °C (-4 °F to +86 °F)
blueCool -30
-30 °C to +40 °C (-22 °F to +104 °F)