In operation
Temperature range of the ambient air:
• -25 °C to +40 °C (-13 °F to 104 °F)
[1]
Relative humidity:
• up to 50 % at 40 °C (104 °F)
• up to 90 % at 20 °C (68 °F)
Transport and storage
Storage in a closed room, temperature range of the ambient air:
• -30 °C to +70 °C (-22 °F to 158 °F)
[1]
Relative humidity
• up to 90 % at 20 °C (68 °F)
[1]
Ambient temperature dependent on coolant! Observe the coolant temperature range of the torch coo-
ling
5.3.3 Welding torch cooling system
Material damage due to unsuitable coolants!
Unsuitable coolant, coolants mixed with other types / liquids or use in an unsuitable tempera-
ture range will result in material damage and loss of the manufacturer's warranty!
• Operation without coolant is not permitted! Dry running will destroy the cooling components
such as the coolant pump, welding torch and hose packages.
• Only use the coolants described in these instructions for the specified ambient conditions
(temperature range) > see 6.1.1.1 chapter.
• Do not mix coolants of different types (including those described in these instructions).
• When changing the coolant, all liquid must be replaced and the cooling system flushed.
Dispose of the coolant in accordance with local regulations and the material safety data sheets.