Profiles for the Profibus DP module
7.4.1
Default profile (switch position 0)
The module uses a data capacity of 10 bytes for input data and 11 bytes for output data and should be
used if all input and output data is required.
Actuation data
Byte
no.
Bit no.
Function
Description
0 0 Start
Bit allocation:
0
1
Start signal to initiate the welding process
Signal stop on system
Signal start on system
0 1 Robot
ready
Bit allocation:
0
1
Safety signal for rapid shut-down
No ready message from robot, no start possible,
rapid shut-down carried out in the process
Robot ready message, start is possible
0
2
Select welding mode
Bit allocation:
0
1
Select between normal/pulse welding
Normal welding active
Pulse welding active
0
3
Select operating mode
Bit allocation:
0
1
Select between non-latched/special non-latched
Non-latched operating mode
Special non-latched operating mode
0 4 Reserved
-
0 5 JOB
mode
Bit allocation:
0
1
Signal activates the JOB mode function
JOB mode switched off
JOB mode active
0 6 WF switching (optional)
Bit allocation:
0
1
Switches between 2 wire drive units
WF case 1 is active
WF case 2 is active
0
7
Error reset
Acknowledgement signal for system error
1
0
Gas test 1
Bit allocation:
0
1
Manual check of the process gas supply
Gas supply off
Gas supply on
1 1 Inching
Bit allocation:
0
1
Signal for wire inching function on the wire feed
drive
Inching off
Inching on
1 2 Reverse
inching
Bit allocation:
0
1
Signal for reverse wire inching function
Reverse inching off
Reverse inching on
1 3 User-defined
output
Bit allocation:
0
1
Switches the user-defined relay output on the bus
module
Relay not switched
Relay switched