Rectifying faults
General operating problems
46
099-005333-EW501
19.03.2014
7.3.2
Resetting all JOBs
NOTE
JOBs 1
–128 and 170–256 will be reset.
Custom JOBs 129
–169 are maintained.
ENTER
3 s
EXIT
RESET
3 s
3 s
JOB-
LIST
JOB-
LIST
Figure 7-2
Display
Setting/selection
Reset to factory settings
The RESET will be done after pressing the button.
The menu will be ended when no changes are done after 3 sec.
7.4
General operating problems
7.4.1
Interface for automated welding
WARNING
No function of the external interrupt equipment (emergency stop switch)!
If the emergency stop circuit has been realised using an external interrupt equipment
via the interface for automated welding, the machine must be configured for this setup.
If this is not observed, the power source will ignore the external interrupt equipment
and will not shut down!
• Disconnect jumper 1 on PCB T320/1 (Tetrix) or M320/1 (Phoenix / alpha Q)!