Design and function
Transport and installation
099-011445-EW501
24.06.2021
19
5.3.2.1 Permitted torch coolant
Coolant
Temperature range
blueCool -10
-10 °C to +40 °C (14 °F to +104 °F)
KF 23E (Standard)
-10 °C to +40 °C (14 °F to +104 °F)
KF 37E
-20 °C to +30 °C (-4 °F to +86 °F)
blueCool -30
-30 °C to +40 °C (-22 °F to +104 °F)
5.3.2.2 Maximal hose package length
All information relates to the total hose package length of the complete welding system and presents ex-
emplary configurations (of components of the EWM product portfolio with standard lengths). A straight
kink-free installation is to be ensured, taking into account the max. delivery height.
Pump: Pmax = 3,5 bar (0.35 MPa)
--------------------------------------------------------------------------------------------------------------------- ►
Power source
Hose package
Wire feeder miniDrive
Welding torch
Max.
Compact
(25 m / 82 ft.)
(5 m / 16 ft.)
30 m
98 ft.
(20 m / 65 ft.)
(5 m / 16 ft.)
Decompact
(25 m / 82 ft.)
(5 m / 16 ft.)
(15 m / 49 ft.)
(10 m / 32 ft.)
(5 m / 16 ft.)
Pump: Pmax = 4.5 bar (0.45 MPa)
--------------------------------------------------------------------------------------------------------------------- ►
Power source
Hose package
Wire feeder miniDrive
Welding torch
Max.
Compact
(25 m / 82 ft.)
(5 m / 16 ft.)
30 m
98 ft.
(30 m / 98 ft.)
(5 m / 16 ft.)
40 m
131 ft.
Decompact
(40 m / 131 ft.)
(5 m / 16 ft.)
45 m
147 ft.
(40 m / 131 ft.)
(25 m / 82 ft.)
(5 m / 16 ft.)
70 m
229 ft.